duplex{auto|half|full}
e1channel-grouptimeslots
Purpose
UsethiscommandtocreateanE1channelizedsubinterfacewhen
CE3interfaceworksinchannelizationmode.Deletethisinterface
withthenocommand.
CommandModes
Channelizationconguration
Syntax
e1<line>channel-group<channel-number>timeslots<time
slots>
noe1<line>channel-group<channel-number>
Syntax
Description
<line>E1number ,therange1~16
<channel-number>Channelnumber ,canonlybe1
<timeslots>Timeslotnumber ,thetimeslots1~31haveto
beassignedtoaninterfaceatonetime.
Instructions
ItisonlyappliedtoZXR10GER,ZXR10T64E/T128.
Example
Thisexampledescribeshowtocongureaninterface,theE1num-
beris1,thechannelnumberis1,anddeletethisinterfaceatlast.
ZXR10(config)#controllerce3_3/1
ZXR10(config-control)#e11channel-group1timeslots1-31
ZXR10(config-control)#nochannel-group1
e1clocksource
Purpose
UsethiscommandtoconguretheclocksourceofinterfaceE1.
Restorethedefaultvaluewiththenocommand.
CommandModes
Channelizationconguration
Syntax
e1<line>clocksource{internal|line}
noe1<line>clocksource
Syntax
Description
<line>E1number ,therange1~16
lineLineclock
internalInternalclock
Defaults
Clockmodeisinternalbydefault.
Instructions
ItisonlyappliedtoZXR10GER,ZXR10T64E/T128.
Example
Thisexampledescribeshowtoconguretheclocksourceofthe
No.1E1channelaslineclock.