Chapter Error! Style not defined. Error! Style not defined.
2-23
W140A through a bi-directional Ethernet connector.
2. Protecting the Ethernet cable
As part of the Ethernet cable is exposed outdoor, the said segment of the
Ethernet cable must be covered by a shrinkable sleeve (for normal temperature)
or a PVC tube.
Note:
Observe the installation direction of the shrinkable sleeve (for normal temperature).
When using the waterproof tape, you should bind the tape around the joints carefully,
wrap the outer cover with the insulting tape, and then apply the silica gel carefully.
3. Installing the Ethernet cable
4. Fixing the Ethernet cable
2.3.6 Lightning Protection System
A safe grounding system should be able to protect the outdoor equipment from direct
lightning strike and inductive lightning strike. The W140A can withstand a 2200 kV
inductive lightning strike within 10m, 5m, 3m and 1m from the discharge electrode. It
can also withstand a 2200 kV simulated direct lightning strike (the discharge electrode
discharges to the lightning arrester of the W140A directly).
Fig. 2.3-8 shows how to install the lightning protection system of the W140A.