Do you have a question about the Zublin Swiss Garde 360 Presence DALI Master 16m and is the answer not in the manual?
Type | Presence detector |
---|---|
Mounting Type | Ceiling |
Detection Range | 16 m |
DALI | Yes |
Application | Indoor |
Category | Presence Detector |
Function | Lighting Control |
Model | Swiss Garde 360 Presence DALI Master 16m |
Technology | Passive infrared (PIR) |
Detection Angle | 360° |
Covers essential safety measures and installation compliance with national standards.
Explains heat misplacement detection and automatic light activation.
Details automatic light regulation based on ambient brightness and power saving.
Details connections for phase, neutral, switching output, slave detectors, and manual control.
Describes standard installation wiring and optional 'S' connection for slave detectors.
Explains wiring for manual switching or dimming via button connection 'R' or T1/T2.
Details how to use the push button for light control and dimming.
Outlines activation and control sequence for semi-automatic operation via button or remote.
Describes LED behavior and general caution for setting detector values via controller or remote.
Details the sensitivity and range adjustment controller for optimal detection.
Explains the timer setting for light run-on duration after the last movement.
Describes the test function for checking the detection area with a short follow-up time.
Regulates response threshold and mixed light value for constant light control based on ambient light.
Controls basic or orientation lighting run-on time after detection, with selectable durations.
Allows selection of orientation light brightness levels (10%, 20%, 30%).
Describes the all-round detection area and dense network for optimal function.
Explains how mounting height, walking direction, and temperature difference affect range.
Addresses issues with the lamp failing to activate, checking twilight value and mains voltage.
Solves problems of false triggering or failure to turn off due to sensitivity or interference.
Provides solutions for lamp behavior during power surges and incorrect brightness after switching.
Solves problems of the unit switching on during daylight and notes post-connection readiness.
Covers nominal voltage, switching output type, and ballast capacity.
Details slave connection, time setting, push button functions, and orientation light settings.
Specifies detection range based on mounting height and installation height recommendations.
Provides device dimensions, RA design, and protection rating (IP 20, class II).