LIMITED WARRANTY
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of ve years from the date
of purchase. Decorative nishes warranted for one year. We will replace at no costs goods that prove defective provided we are notied in
writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly maintained and
used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages whatsoever, includ-
ing incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the defective goods. Before
installation and use, the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk
and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability is expressly excluded. If the
products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a period of three years and shall be
limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are approximate and are not guaranteed.
Sensor-Operated Concealed SystemsSensor-Operated Exposed Systems
ZEMS6000AV
ZEMS6200AV
ZEMS6000AV-2
ZEMS6200AV-2
ZEMS6000AV-3
ZEMS6200AV-3
ZEMS6001AV
ZEMS6201AV
ZEMS6003AV
ZEMS6203AV
AquaSense
®
ZEMS G2 Series
Automatic Systems Sensor-Operated
Flushometer
Installation,
Operation,
Maintenance
and
Parts
Manual
Patented and Patents Pending
ZEMS6140AV
ZEMS6240AV
ZEMS6152AV
ZEMS6252AV
ZEMS6153AV
ZEMS6253AV
ZEMS6190AV
ZEMS6290AV
ZEMS6195AV
ZEMS6295AV
ZEMS6197AV
ZEMS6297AV
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov
Question and Answer IconNeed help?

Do you have a question about the ZURN ZEMS6000AV and is the answer not in the manual?

ZURN ZEMS6000AV Specifications

General IconGeneral
ModelZEMS6000AV
CategoryMeasuring Instruments
Power SupplyBattery
Pressure Rating150 psi
Sensor TypeElectromagnetic
OutputPulse
MaterialBrass
Temperature Range32°F (0°C)
Power SourceBattery
Operating Pressure15-150 PSI

Summary

Electrical System

AC/DC Power Supply Options

Details AC/DC power supply options for flushometers and converters.

Electrical Hook-up Diagram

Explains wiring connections between sensor, actuator, and power converter.

Sensor Installation Procedures

Locate Sensor Box

Instructions for locating and installing the sensor box in the wall.

Mount Automatic Sensor

Guide for mounting the automatic sensor into the electrical box.

Install Top Bracket

Steps for fastening the top bracket to the electrical box.

Install Cover Plate

Procedure for fitting and fastening the sensor cover plate.

Mechanical Installation and Setup

Control Stop Installation

Steps for installing and adjusting the control stop assembly.

Flush Valve Installation

Guide on attaching the flush valve to the control stop.

Motor Actuator Installation

Drill Mounting Hole

Instructions for drilling the mounting hole for the actuator.

Pull Actuator Cable

Procedure for pulling the actuator cable through the wall.

Install Actuator Escutcheon

Guide for installing the actuator escutcheon onto the actuator pipe.

Secure Cable and Mount Actuator

Steps for securing cable and mounting the actuator.

Sensor Range Customization

Calibration Instructions

Detailed steps for calibrating the sensor range for optimal performance.

Verify Closet Installation Calibration

Procedures to verify correct sensor calibration for closet installations.

Activating Motor Actuator

Explanation of how the sensor activates the motor actuator.

Care and Cleaning

Guidelines for cleaning and maintaining the flushometer and sensor.

Troubleshooting Guide

Valve Operation Issues

Addresses problems like valve not operating or short flushing.

Activation and Flushing Problems

Covers issues like ghost flushing or insufficient water volume.

Noise and Splash Issues

Solutions for noisy or splashing flush valve operations.

Parts Identification

ZEMS G2 Valve Components

Diagram and list of key components for ZEMS G2 valves.

ZEMS G2 Valve Parts List

Detailed list of parts for ZEMS G2 valves, including repair kits.

Valve Repair Parts

Specific components for valve repair and control stop assemblies.