Chapter 22 Authentication & Accounting
GS-3012/GS-3012F User’s Guide
180
22.3.2.2 Attributes Used for Accounting Exec Events
The attributes are listed in the following table along with the time that they are sent (the
difference between Console and Telnet/SSH Exec events is that the Telnet/SSH events utilize
the Calling-Station-Id attribute):
22.3.2.3 Attributes Used for Accounting IEEE 802.1x Events
The attributes are listed in the following table along with the time of the session they are sent:
Table 62 RADIUS Attributes - Exec Events via Console
ATTRIBUTE START INTERIM-UPDATE STOP
User-Name Y Y Y
NAS-Identifier Y Y Y
NAS-IP-Address Y Y Y
Service-Type Y Y Y
Acct-Status-Type Y Y Y
Acct-Delay-Time Y Y Y
Acct-Session-Id Y Y Y
Acct-Authentic Y Y Y
Acct-Session-Time Y Y
Acct-Terminate-Cause Y
Table 63 RADIUS Attributes - Exec Events via Telnet/SSH
ATTRIBUTE START INTERIM-UPDATE STOP
User-Name Y Y Y
NAS-Identifier Y Y Y
NAS-IP-Address Y Y Y
Service-Type Y Y Y
Calling-Station-Id Y Y Y
Acct-Status-Type Y Y Y
Acct-Delay-Time Y Y Y
Acct-Session-Id Y Y Y
Acct-Authentic Y Y Y
Acct-Session-Time Y Y
Acct-Terminate-Cause Y
Table 64 RADIUS Attributes - Exec Events via Console
ATTRIBUTE START INTERIM-UPDATE STOP
User-Name Y Y Y
NAS-IP-Address Y Y Y
NAS-Port Y Y Y
Class Y Y Y
Called-Station-Id Y Y Y
Calling-Station-Id Y Y Y
NAS-Identifier Y Y Y