Chapter 15 Power Over Ethernet
GS1500-24P User’s Guide
118
Status This field displays if a PD is currently being fed power.
Priority When the total power requested by the PDs exceeds the total PoE power
budget on the Switch, you can set the PD priority to allow the Switch to
provide power to ports with higher priority first.
• Critical has the highest priority.
• High has the Switch assign power to the port after all critical priority
ports are served.
• Low has the Switch assign power to the port after all critical and high
priority ports are served.
Class This shows the IEEE 802.3af power classification of the PD.
This is a number from 0 to 4, where each value represents a range of power
(W) and power current (mA) that the PD requires to function. The ranges
are as follows.
• Class 0 - Default, 0.44 to 12.94
• Class 1 - Optional, 0.44 to 3.84
• Class 2 - Optional , 3.84 to 6.49
• Class 3 - Optional, 6.49 to 12.95
• Class 4 - Reserved (PSEs classify as Class 0)
Consumptio
n Power
(W)
This field displays the current amount of power consumed by the PD from
the Switch on this port.
Table 38 Configuration > PowerOverEthernet (continued)
LABEL DESCRIPTION