Chapter 5 Initial Setup Example
GS1500-24P User’s Guide
48
1 Click Configuration > VLAN > Static VLAN in the navigation panel and the
following screen will display.
2 In the Static VLAN screen, enter 2 in the VLAN ID field and enter a descriptive
name in the VLAN Name field for the VLAN group.
3 Since the VLAN2 network is connected to port 1 on the Switch, select Untagged
on port 1 to make it a permanent member of the VLAN2 group only.
4 To ensure that VLAN-unaware devices (such as computers and hubs) can receive
frames properly, make sure Untagged is selected as above so the Switch
removes VLAN tags before sending.
5 Click Add / Modify to save the settings to the run-time memory. Settings in the
run-time memory are lost when the Switch’s power is turned off.
5.1.2 Setting Port VID
Use PVID to add a tag to incoming untagged frames received on that port so that
the frames are forwarded to the VLAN group that the tag defines.