EasyManua.ls Logo

ZyXEL Communications MSC1000G - Switch Port Pvid Command

ZyXEL Communications MSC1000G
1168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 33 switch Commands
Management Switch Card User’s Guide
1027
33.14.11 switch port pvid Command
Syntax:
switch port pvid <giga-port> <vid>
where
This command sets the Port VLAN ID assigned to untagged frames or priority frames (0 VID)
received on this port(s).
The following example sets the PVID of uplink interface 1 to 76.
33.14.12 switch port show Command
Syntax:
switch port show
This command displays the settings for the system’s Gigabit Ethernet interfaces. An example is
shown next.
33.14.13 switch port speed Command
Syntax:
switch port speed <giga-port> <speed>
where
<pvid>
=
The default Port VLAN ID (PVID) assigned to untagged frames or priority-tagged
frames received on this port. 1~4094.
ras> switch port pvid up1 76
ras> switch port show
port name en mode speed fc pvid prio gvrp ftype vt dscp
----- --------------- ---- ---- ------ ---- ---- ---- ---- ----- ---- ----
sub1 Subtend1 V up auto - 1 0 - all - -
sub2 Subtend2 V up auto - 1 0 - all - -
up1 Uplink1 V up auto - 1 0 - all - -
up2 Uplink2 V up auto - 1 0 - all - -
<giga-port>
=
This represents 1000BaseT uplink ports. The port speed is fixed for subtending
ports and/or SFP slots that use a fiber-optic interface. Specify an individual
interface if trunking is not enabled. Use
tup|all if trunking is enabled.
<speed>
=
The port’s speed and duplex mode.
Use
auto|1000F|100F|100H.
Auto or 1000 (Mbps) or 100 (Mbps) is to match the port speed of the WAN switch
to which this port is to connect.
F is for full duplex communications or H for half duplex communications.

Table of Contents