Chapter 34 sys Commands
Management Switch Card User’s Guide
1047
34.3.22 sys monitor set Command
Syntax:
sys monitor set <slot> <volt|temp|fan|cpu|mem|pbuf> <index> <high-limit> <low-limit>
where
<slot>
=
The main chassis slot where the card is located. Use the slot number of the MSC
when you configure the fan, memory, or packet buffer limits.
volt|temp|fan|
cpu|mem|pbuf
=
volt: Set the voltage tolerance range.
temp: Set the temperature tolerance range.
fan: Set the rotations per minute (RPM) tolerance range for a fan.
cpu: Set the threshold for CPU usage.
mem: Set the threshold for memory usage.
pbuf: Set the threshold for usage of the packet buffer for transmission and
receiving.
<index>
=
The index number of the sensor.
The power supply for each voltage has a sensor that is capable of detecting and
reporting if the voltage falls out of the tolerance range. The card voltage sensors
are as follows.
MSC: 1 = 2.5 V, 2 = 1.25 V, 3 = 3.3 V, 4 = 1.3 V, 5 = 15 V
ADSL line card: 1 = 1.2 V, 2 = 1.8 V, 3 = 3.3 V, 4 = 20.5 V
SHDSL line card: 1 = 1.8 V, 2 = 3.3 V, 3 = 15.0 V
VDSL line card: 1 = 3.3 V, 2 = 12.0 V, 3 = 1.2 V, 4 = 1.2 V, 5 = 1.8 V
VoIP line card: 1 = 1.3 V, 2 = 2.5 V, 3 = 3.3 V, 4 = 3.3 V, 5 = 5.0 V
Ethernet line card: 1 = 2.5 V, 2 = 1.2 V, 3 = 3.3 V, 4 = 5.0 V
The management switch card has temperature sensors that are capable of
detecting and reporting if the temperature rises above the threshold.
Each card has three temperature sensors (1~3).
Each fan has a sensor that is capable of detecting and reporting if the fan speed
falls below the threshold of 2000 RPM.
The system has six fans (1~6).