Management Switch Card User’s Guide 1105
CHAPTER 38
Troubleshooting
This chapter offers some suggestions to solve problems you might encounter. The potential
problems are divided into the following categories. See Chapter 39 on page 1115 for default
settings.
38.1 Power, Hardware Connections, and LEDs
The MSC does not turn on. None of the LEDs turn on.
Make sure the MSC is properly installed in the slot and the system power is properly connected and
turned on.
Refer to the IES-6000M or IES-5000 Series Users Guide for directions
and safety warnings on installing the management switch card and
power connections for the IES-5000.
The ALM LED is on.
An alarm has been detected on the MSC, the Integrated Ethernet Switch fan or the INPUT ALARM
terminals. Examples of an alarm on the MSC are when the MSC’s voltage or temperature is outside
of the normal range.
Check the logs to see the cause of the alarm. Take appropriate measures to remove the cause of
the alarm. For example, you may need to change the fan module if the fans are not operating
normally (see the IES-6000M or IES-5000 Series Users Guide for directions).
One of the LEDs does not behave as expected.
1 Make sure you understand the normal behavior of the LED. See Section 2.2 on page 56.
2 Check the hardware connections. See Section 2.3 on page 56.
3 Inspect your cables for damage. Replace any damaged cables.