Chapter 20 alarm Commands
Management Switch Card User’s Guide
688
The following example displays the critical level alarms for all alarm categories and conditions.
20.3.9 alarm tablelist Command
Syntax:
alarm tablelist [<alarm>|all] [<severity>|all] [<fac>|all][<target>[,<target>]]
[<condition>|all]
where
This
command displays the supported alarm list and report settings.
ras> alarm show critical all
[current card alarm]
id state card type heat vol mon down out
--- --------- --------------- ---------------------
1 standby MSC1000G - - - - -
2 active MSC1000G - - - - -
3 - - - - - -
4 - ALC1248G-53 - - - V V
5 active ALC1248G-53 - - - - -
6 - - - - - -
7 - ALC1248G-51 - - - V V
8 - - - - - -
9 - ALC1248G-53 - - - V V
10 - ALC1248G-53 - - - V V
[current alarm list]
no alarm condition severity timestamp source
------ ------ ------------------------ -------- -------------- --------------
1 eqpt +FAN_ERROR critical 12/14 13:46:41 slot 2
2 eqpt +FAN_ERROR critical 12/14 13:46:41 slot 2
3 eqpt +FAN_ERROR critical 12/14 13:46:41 slot 2
4 eqpt +FAN_ERROR critical 12/14 13:46:41 slot 2
5 eqpt +FAN_ERROR critical 12/14 13:46:41 slot 2
6 eqpt +FAN_ERROR critical 12/14 13:46:41 slot 2
7 eqpt +DC_POWER_FAIL critical 12/14 13:46:21 slot 2
<fac>
=
The log facility (local1~local7) that has the device log the syslog messages to
different files in the syslog server. See your syslog program’s documentation for
details.
<target>
=
snmp|syslog|all The type of alarm messages that the device is to send
(SNMP, syslog or all).