Click Advanced > Remote MGMT > TR-069 to open the following screen. Use this screen to
configure your GPON Device to be managed by an ACS.
Figure 61 Remote Management: TR-069
The following table describes the fields in this screen.
Table 44 Remote Management: TR-069
LABEL DESCRIPTION
Active Select this to activate remote management via TR-069 on the WAN.
ACS URL Enter the URL or IP address of the auto-configuration server.
User Name Enter the TR-069 user name for authentication with the auto-configuration server.
Password Enter the TR-069 password for authentication with the auto-configuration server.
Connection Request
URL
This shows the connection request URL.
The ACS can use this URL to make a connection request to the GPON Device.
Connection Request
User Name
Enter the connection request user name.
When the ACS makes a connection request to the GPON Device, this user name is
used to authenticate the ACS.
Connection Request
Password
Enter the connection request password.
When the ACS makes a connection request to the GPON Device, this password is used
to authenticate the ACS.
PeriodicInform
Enable
Select this to have the GPON Device periodically send information to the auto-
configuration server.
PeriodicInform
Interval
Enter the time interval (in seconds) at which the GPON Device sends information to
the auto-configuration server.
PeriodicInform Time
Enable
Select this to have the GPON Device send information to the auto-configuration server
at a specified time.
PeriodicInform Time Enter the date and time at which the GPON Device sends information to the auto-
configuration server. For specifying time, the 24 hour format is used.
Apply/Save Click this button to save your changes back to the GPON Device.
Cancel Click Cancel to begin configuring this screen afresh.