FAQ:Error & Miscellaneous Codes
11
Error & Miscellaneous Codes.
Error Codes: These may be displayed on the seven segment display.
1. “UNBI” : Probe has been unbound (unpaired) from the cooktop by the user.
2. “BAT”: Probe battery is running low during precision cooking.
3. “PROB” : No probe connection or connection was lost, cannot use Rapid, Gentle Mode or
Multi Stage Cooking when this error is present .
4. “POT”: No pot detected on the cooking surface.
Cooking Noise
Slight sounds may be produced by dierent types
of cookware. Heavier pans such as enameled
cast iron produce less noise than a lighter weight
multi-ply stainless steel pan. The size of the pan,
and the amount of contents, can also contribute to
the sound level.
A “humming” noise will be heard from the cooling
fan when it turns on to cool the induction elements;
it is normal for it to come on shortly aer the coil
turn on to cook.
You may hear a slight “Buzz” when cooking at
higher power levels, this is normal. The sound
depends on the type of pot being used. Some pots
will “Buzz” louder depending on the material. A
“Buzz” sound may be heard if the pan contents are
cold. As the pan heats, the sound will decrease. If
the power level is reduced, the sound level will go
down.