SEITE 2
-
148 x 210 mm
-
44000737039/03
-
SCHWARZ
-
11-249 (sr)
2
Capsules: Diameter max.19 mm,
total length max. 58 mm,
length without tubes max.38 mm,
weight max.7g
Housing: Housing and protective cover
made of high impact-resistant
plastics
Mixing speed: 4650 rpm for 7g-capsules
Operating temperature: 18°C…40°C/64°F…104°F
Relative humidity: max. 80% at 31°C/88°F,
max. 50% at 40°C/104°F
Main voltage: 100 V, 120 V, 230 V, 50/60 Hz,
for preset voltage refer to the
rating plate
Power requirements: 330 VA
Fuses: 230 V: 2 A time-lag fuse
120 V: 3.2 A time-lag fuse
Dimensions: (W x H x D)
195 x 160 x 195 mm
Weight: 3750 g
Continous sound
pressure level: >70 dB(A)
Year of manufacture: See rating plate
5. Installation
Prior to the initial start-up, remove the transport
safety guard.
Connect the CapMix unit to the power supply and switch
on the unit with the power switch on the back of the
device.The display shows the mixing time of program1.
The following basic settings are preset at the factory:
Program 1 (key “P1”): 5 sec mixing
Program 2 (key “P2”): 7 sec mixing
Program 3 (key “P3”): 9 sec mixing
Program 4 (key “P4”): 12 sec mixing
Fixed time (key “10 s”): 10 sec mixing
Fixed time (key “15 s”): 15 sec mixing
5.1 Setting the mixing time
Mixing times in the range of 1 sec to 39 sec may be
selected. By pressing the keys “+” or “
-
” the device
increases or decreases, respectively, the mixing time by
1sec. Depressing and holding the “+” or “
-
” keys, the
device continues to count up or down, respectively.
5.2 Changing the basic settings
Set the mixing time as described above, then depress
one of the program buttons, “P1”
-
“P4”, until two short
signals are issued. This confirms that the desired settings
have been stored in the selected program.
14. Only appropriately labeled original 3M ESPE replace -
ment parts may be used in the repair and maintenance
of this unit. Any damage resulting from the use of
third-party replacement parts voids the liability of
3M ESPE.
15. Do not attempt to operate this unit by bypassing the
protective mechanisms (e.g. by turning off the auto-
matic shut-off switch on the cover of the unit). Violation
of the safety regulations may cause serious injury and
voids all warranties and guarantees.
16. Do not expose the device to solvents, flammable
liquids, and strong heat sources as these may damage
the plastic housing.
17. Cleaning the unit, ensure that no cleaning agent
enters the device since this may lead to electric short-
circuiting or hazardous malfunctions.
18 .
Pay attention to capsule leak tightness when mixing.
Capsules that are not leak tight contaminate the
device with mercury. Contaminated devices cannot be
repaired and must be disposed of as contaminated
waste according to local laws.
See the safety data sheet for the amalgam used for
first aid, measures to take in case of unintended
release, handling, storage, exposure limitation, and
personal protective clothing.
2. Product Description
The CapMix unit, manufactured by 3M ESPE, is a mixing
device for dental filling materials and cements in capsules.
Desired mixing times may be programmed into the mixing
programs “P1”
-
“P4”. Moreover, two pre-set mixing times,
“10 s” and “15s”, can be selected.
Operating Instructions should not be discarded for the
duration of product use.
3. Fields of Application
Dental materials packaged in capsules with a max.capsule
weight of 7g.
Capsules with a weight of more than 7g must not be used!
4. Technical Data
Drive unit: Ball-bearing motor with
integrated self-resetting
overheat cut-off
Operating mode: Short-term operation,
1min On/7 min Pause
Controller: Microprocessor-controlled,
high-precision mixing time
control by quartz timing
mechanism
Capsule holder: Self-locking