9 
2.14  Check for buffer clamp. If the clamp is partially actuated, remove the connector and repeat at Section 
2.12 
2.15  Hold  the  cable  holder  by  both  sides.  SLOWLY  slide 
back the connector to insert fiber into the connector. 
Caution: Do NOT TOUCH CABLE until splice is actuated 
at Section 2.17.   
2.13  Be  aware  of  fiber  guide  protruding  downward  until 
splice is acutated 
Caution: Do NOT PUSH UP fiber guide or connector may 
pop out from cable holder 
2.16  Check for marking on buffer at the end of buffer clamp. 
 
  If  marking  is  not  at  this  position,  pull  out  the  sliding 
head and check for fiber length again per Section 2.10. 
And insert fiber again per Section 2.15