4-noks SRL - Via Per Sacile, 158 - Francenigo di Gaiarine (TV) - Italy
Tel. +39 0434 768462 - Fax +39 0438 694617 - info@4-noks.com - www.4-noks.com
Quick
Guide
+05T408121R1.1 Ellios4you Pro Quick Guide_EN 12/05/2015
ELIOS4YOU Pro
ID CODE:YYYYY
123456789XXXXX
ID CODE:YYYYY
123456789XXXXX
Problem Solutions
1. I can’t see my PV system
energy generation in the
App’s home Page
a. Change current clamps (CT) versus (white label) by inverting the green dot or the inside current clamp arrow position.
b. Check that the current clamps core is not broken or cracked inside.
2. The energy generation visible
on the App is definitely less
than the value read from the
inverter
a. Be sure that the Elios4you is powered from the same line of the 2 current clamps.
b. Check that the current clamps (white label) are perfectly closed: any strong pressure should be need to clamp the cable
properly
c. Make sure that you have kept a correct correspondence between the sequence of voltages to bring power to the main circuit
breaker and the sequence in which the CT are positioned in the various cables .
3. Consumption graph has the
same shape of production
graph line
a. Be sure that the mains CTs (yellow label) clamp all lines coming from the Mains Meter before they undergo branching within the
electrical system.
b. Check that the current clamps core is not broken or cracked inside.
4. It seems that consumption
values are shown in the
“grid” icon
a. Be sure that the mains CTs (yellow label) clamp all lines coming from the Mains Meter before they undergo branching within the
electrical system.
5. I can never see purchased
energy in my system
a. Be sure that the mains CTs (yellow label) clamp all lines coming from the Mains Meter before they undergo branching within the
electrical system.
6. During the night the
consumption is zero, while
during the day is always
more than normal value
expected
a. Be sure that the mains CTs (yellow label) clamp all lines coming from the Mains Meter before they undergo branching within the
electrical system.
b. Make sure that you have kept a correct correspondence between the sequence of voltages to bring power to the main circuit
breaker and the sequence in which the CT are positioned in the various cables .
All models are compliant to directive 2004/108 CE - 2006/95 CE - directive 99/5 CEE
The appliance (or the product) must be disposed of separately in accordance with the local regulations regarding disposal.
Elios4you Pro-xx
Current Transformers
ID Code Label
READ THESE INSTRUCTIONS BEFORE INSTALLING
1. After device installation and after having it powered on, download the free App Elios4you on your own device (smartphone or tablet) from Playstore
(Android) or App Store (iOS)
2. Open the App and start the wizard, following the steps visible on your smartphone/tablet (read the Elios4you APP Quick Guide for further information)
3. Set correct parameters for your PV system and your energy provider using the App menu:
- Press “Menu” button
- Select “Parameter Settings”
- Select “Energy Management” and set values
- Press OK when finished to save new values
4. Check that collected data are correct:
- Press “Home” button to to go the “Energy performance” page
- Check that energy “Generation” value has similar value as you can read from the inverter
- Check that the energy “Consumption” value is the same of the real time consumption you have in the home
ATTENTION: when Elios4you is configured for internet access through Router/AP, all data are collected even on 4-cloud website.
Go to http://www.4-cloud.org and follow on line instructions for registering. Match your account with the device filling with the USER code on the label of your
Elios4you.
WARNING: remove the cover to the right to access the CONFIG button.
a) b)
Removable Cover
Product Identification:
this document refers to following devices:
Code Product
E4U-PRO Elios4you 3-phase up to 30 kW
E4U-PRO-DE Elios4you 3-phase up to 50 kW
E4U-PRO-EN Elios4you 3-phase up to 50 kW
E4U-PRO-FR Elios4you 3-phase up to 50 kW
E4U-PRO-UK Elios4you 3-phase up to 50 kW
E4U-PRO-LIGHT-DE Elios4you 3-phase up to 15 kW
E4U-PRO-LT-EN Elios4you 3-phase up to 15 kW
EN
ATTENTION
ATTENTION: before installing Elios4you, remove the
label (see picture below) with USER code.
Keep the label in a safe place for future other device
configuration and/or for logging in the website www.4-
cloud.org.
ID CODE: 00000
Register on:
www.4-cloud.org
and associate your device
with USER: XXXXXXXX
ATTENTION: if you are setting a connection
through a Router/AP, data will be visible on
the website after approximately 1 hour from
configuration.
INSTALLATION
The Elios4you Pro family of products are wireless devices designed to monitor and
manage three-phase photovolatic installations (400Vac with neutral) via the Elios4you
APP. The transmitter measures the energy generated of the PV plant, exchanged with the
grid, the household consumption and the self-consumption.
TROUBLE SHOOTING
Installation - Power reading

Other manuals for 4-noks ELIOS4YOU Pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 4-noks ELIOS4YOU Pro and is the answer not in the manual?

4-noks ELIOS4YOU Pro Specifications

General IconGeneral
Brand4-noks
ModelELIOS4YOU Pro
CategoryMeasuring Instruments
LanguageEnglish