WE/XE/SE/XC Series
Quarter-Turn Electric Actuator
Installation & Maintenance Manual
9 12/17/19
www.atcontrols.com IOM8011 REVISION 01
5.3.2. Drive Bushing
Standard drive bushings are ISO 5211 star. Verify
actuator drive bushing matches valve or actuator device
stem before mounting.
Actuator
Size
Std.
Drive
Size
-690 17mm
-1350, 1700 19mm
-2640, 4400, 5200 27mm
-6900, 10500 36mm
-17500, 25900 36mm
Housing Cover
WARNING:
Flamepath surfaces on XE and XC actuators
must not be damaged in any way. DO NOT
FORCE
cover onto actuator body.
Actuator housing covers are attached with bolts in each
corner. Unscrew bolts to remove cover.
Actuator
Size
Bolt Hex
Size
-690 6mm
-1350, 1700 8mm
-2640, 4400, 5200 10mm
-6900, 10500 10mm
-17500, 25900 10mm
Limit Switch Setting
WARNING:
Hazardous voltage. Turn off all power and lock
out service panel before installing or modifying
any electrical wiring. Use caution when
energizing inputs.
CAUTION:
Setting limit switches incorrectly may result in
actuator stopping by the mechanical stops.
This may overheat the motor and force it into
thermal overload. Electrical operation will not
be possible until overload resets. The motor
may eventually fail if repeatedly overheated.
The motor control limit switches and auxiliary switches
have independently adjustable cams.
Switch order from top to bottom of the stack:
CLS = Close motor control
ACLS = Auxiliary close
OLS = Open motor control
AOLS = Auxiliary open.