EasyManuals Logo

A.W. Sperry Instruments AWS DIGISNAP DSA-2002 User Manual

Default Icon
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
sec.3
SPECIFICATIONS
Display:
3.5
digit
LCD,
maximum
reading
1999
with
function
and
decimal
annunciators
Range
Selection:
Manual
rotary
switch
Overrange
Indication:
3
least
significant
digits
blanked
Sampling
Rate:
Approximately
3
times
per
second
Operating
Environment:
-10°
to
50°C
(14°
to
122°F)
at
<
85%
Storage
relative
humidity
Environment:
~—
20°
to
60°C
(—4°
to
140°F)
at
<
Ries
Temp.
90%
relative
humidity
Coefficent:
Less
than
0.07
=
applicable
accurac
x
spec
per
deg
C
for
temp
-10°
to
13°
and
33°
to
50°F
Max.
Conductor
Size:
2.16"
(55
mm)
diameter
Power
Supply:
One
AWS
B-4,
9V
transistor
type
battery
(NEDA
#1604)
Battery
Life:
400
hrs
typical
with
carbon
zinc
cell,
DSA-2002
and
DSA-2002P;
16
hrs
typical
with
carbon
=
zinc
cell,
DSA-2003
Battery
Indicator:
"B"
symbol
appears
on
display
to
Dielectric
indicate
low
battery
Strength:
2500Vac
for
one
minute
Dimensions:
9.7"H
X
2.8"
x
1.4"D
(245
x
70
x
36mm)
Weight:
14.10z.
(400g),
DSA-2002/DSA-2002P
17.70z.
(500g),
DSA-2003
NOTE:
Current
readings
should
not
be
taken
on
conductors
at
a
potential
greater
than
500Vac/dc
above
ground
potential
during
hand
held
operation.
|
RANGES
AC
CURRENT
(average
responding,
calibrated
in
RMS
of
a
sinewave)
ACCURACY
(50/60Hz*)
OVERLOAD
RESOLUTION!
DSA-2002/2002P
DSA-2003
PROTECTION
+(1.0%
rdg
+
2d)
(0-1500A)
+(2.5%
rdg)
(1500-1999A)
*Accuracy
for
40
to
1KHz:
multiply
50/60Hz
accuracy
by
2
+(1.5%
rdg
+
2d)
DC
CURRENT
(average
responding)
ACCURACY
OVERLOAD
RESOLUTION
|
DSA-2002/2002P
DSA-2003
PROTECTION
|
01a
|
No
Ranges
+(1.5%
rdg
+
2d)
3000A
[0008
[1
AC
VOLTAGE
(average
responding,
calibrated
in
RMS
of
a
sinewave)
ACCURACY
(50/60
Hz**)
OVERLOAD
RESOLUTION
|
DSA-2002/2002P
DSA-2003
PROTECTION
|
200v_
[ow
|
+(1.0%
rdg
+
2d)
|
+(1.5%
rdg
+
2d)
:
:
|
08%
9
+20
|
**Accuracy
for
40
to
1KHz:
add
2d
to
50/60Hz
accuracy
DC
VOLTAGE
(average
responding)
ACCURACY
RESOLUTION
|
DSA-2002/2002P
[ev
|
cow
_|
No
Ranges
RESISTANCE
es
OVERLOAD
RESOLUTION|
DSA-2002/2002P
SA-2003
PROTECTION
ee
ees
%
rdg
+
2d)
mie
+(1.5%
rdg
+
2d)
|
cOdvac/ae
No
|
NoRange
|
for
1
minute
SS
Current:
5mA
typical
on
200M
range,
1mA
on
1500
range
DSA-2003
OVERLOAD
PROTECTION
+(1.5%
rdg
+
2d)
PEAK
HOLD
(DSA-2002P)
Peak
hold
display
reads
1/./
2
of
peak
current
or
peak
voltage
(RMS
calibrated
reading
when
a
sinusoidal
AC
current
and
voltage
is
measured).
a
Peak
Response
10ms/100ms
Peak
Hold
Time
Approximately
+1%
of
initial
peak
reading
1
minute
after
peak
hold.
OUTPUT
TERMINAL
(DSA-2003)
OUTPUT
WAVE
OUTPUT
OVERLOAD
RESOLUTION
SHAPE
ACCURACY
PROTECTION
aA’
_
Same
as
+1.5%
rdg
input
current
into
load
S000AdG
O.1mMV/A
wave
shape"
>100KQ
3000A
peak
“Frequency
response:
DC
to
1KHz
(sinusoidal
waveform)
NOTE:
All
accuracies
are
given
for
13°
to
33°C
All
specifications
subject
to
change
without
notice.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the A.W. Sperry Instruments AWS DIGISNAP DSA-2002 and is the answer not in the manual?

A.W. Sperry Instruments AWS DIGISNAP DSA-2002 Specifications

General IconGeneral
BrandA.W. Sperry Instruments
ModelAWS DIGISNAP DSA-2002
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals