12
Cleaning Plates
IMPORTANT: Ensure the unit and plates are fully cooled before maintenance.
Make sure the unit is off and unplugged.
Remove screws from the side of the unit and air vent.
Unit will have 6 screws.
Place the screws in a safe location so they aren’t lost during the maintenance process.
Remove the outside cover.
Use a razor blade to scrape oxidized materials from the plates.
We recommend using a at, straight razor blade for best results.
Be sure to not hit where the plates are soldered together.
If the solder is fractured, the plate will need to be replaced.
Scrape across the grid lines on the plate.
Be sure to scrape the plate evenly.
Clean oxidized materials from the razor blade as needed.
Repeat this process unit the metallic nish of the plate returns.
Use a paper towel or blow across the plates to remove oxidized material that could be left
behind.
Replace the outside cover to the unit.
Place screws back into the unit.
Connect the power cord to test that the unit is still working properly.
There should be a purple glow coming off the ozone plate.
Cleaning the plate will limit spotting and should emit a steady purple glow.
Cleaning the A7K plates regularly will extend the life of the ozone plates.