Do you have a question about the AAA 10.0 GA13 and is the answer not in the manual?
Always wear safety glasses or goggles and appropriate clothing when operating.
Use only non-flammable fluids and clean water; avoid explosive environments or alterations.
Avoid pointing discharge at people/animals; do not allow children to operate; max water temp 140°F.
Product exhaust contains chemicals known to cause cancer/reproductive harm. Wash hands.
Avoid running the pump for more than two minutes without the gun trigger pulled to prevent damage.
Designed for 3400 RPM with a 1" hollow shaft and universal mounting flange for horizontal engines.
Details oil capacity (13 oz / 384 ml) and port connections (inlet/discharge).
Explains Thermal Relief Valve and Detergent Injection System functions.
Steps for mounting the pump to an engine, including shaft key and bolt tightening.
Procedure for using the detergent siphon hose for low-pressure chemical application.
Warning against running in bypass mode for over two minutes; recommended shutdown procedure.
Caution regarding potential exposure to hot surfaces, pressure, or moving parts during maintenance.
Covers checking oil level, changing pump oil, and recommended oil types and intervals.
Instructions for checking, cleaning, and reinstalling the water inlet filter.
Advice on using pump guard for storage over 30 days or in freezing temperatures.
Manufacturer disclaims warranties for merchantability/fitness and is not liable for consequential damages.
Details specific conditions not covered, such as rental use, abuse, accident, and improper installation.
High pressure pump defects in material and workmanship are covered for five years from purchase.
Lists symptoms like oil leaks, premature failure, no flow, and low pressure.
Provides solutions for identified symptoms, including replacing parts and adjusting settings.