Installation and User Manual
H
B
Series
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
FOR YOUR SAFETY
EXTINGUISH ANY OPEN FLAME
DO NOT TOUCH ANY ELECTRICAL SWITCH
DO NOT TRY TO LIGHT ANY APPLIANCE
DO NOT USE ANY PHONE IN YOUR BUILDING
IMMEDIATELY CALL YOUR GAS SUPPLIER
FROM A NEIGHBOR’S PHONE. FOLLOW THE
GAS SUPPLIER’S INSTRUCTIONS.
IF YOU CANNOT REACH YOUR GAS
SUPPLIER, CALL THE FIRE DEPARTMENT.
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
WARNING
Package Units
& Air Handlers
R-410A Package
Air Handler
R-410A DX or Chilled Water Cooling
Gas, Electric or Hot Water Heat
Bottom or Side Discharge
Question and Answer IconNeed help?

Do you have a question about the AAON HB Series and is the answer not in the manual?

AAON HB Series Specifications

General IconGeneral
RefrigerantR-410A
Heating OptionsGas, Electric, Hot Water, Steam
Compressor TypeScroll
Cabinet ConstructionHeavy-gauge galvanized steel
Coil MaterialAluminum fins with copper tubes
Voltage208/230V or 460V, 3-phase
DimensionsVaries by model
WeightVaries by model

Summary

1. Description

Important Safety Information

Crucial safety warnings and notes for installation, operation, and maintenance.

2. Model Number Description

3. User's Information

Modulating Hot Gas Reheat and Hot Gas Bypass Systems on DX Units

Explanation of optional Hot Gas Reheat and Bypass systems for DX units.

4. Delivery

Receipt & Inspection

Procedures for inspecting the unit for damage upon arrival and handling claims.

5. Installation

Codes & Ordinances

Requirements for conforming to local building codes and industry standards.

Service & Installation Clearances

Minimum clearances required for unit service access and airflow.

Setting the Unit

Instructions for properly leveling and positioning the unit on a slab or curb.

Electrical

Instructions for connecting power supply and ensuring proper electrical grounding.

Standard Control Board

Overview of the standard control board and its functions.

Thermostat

Guidelines for thermostat location, wiring, and settings.

Optional Control Board

Information on the optional control board and its features.

Economizer Option

Details on the economizer option, sensors, and controls.

Return Air Bypass Option

Explanation of the return air bypass option for dehumidification.

External Control Inputs to Control Board

Diagram and notes on external control input terminals on the control board.

Modulating Hot Gas Reheat

Lockout Modes

Conditions that cause heating or cooling modes to lock out.

Gas Piping

Gas Pressure Regulator & Over-Pressure Protection Device (Optional)

Requirements for gas pressure regulators and over-pressure protection devices.

6. Start-Up

Procedures

Steps to follow before powering on or starting the unit.

Pre-Startup Check Out

Essential checks before starting the equipment, like wiring and panels.

DX Cooling

Specific start-up procedures for DX cooling units.

Gas Heating

Specific start-up procedures for gas heating units.

Electric Heating

Specific start-up procedures for electric heating units.

Commissioning

Process of verifying and documenting system performance.

7. Operation & Maintenance

General

Importance of a maintenance schedule for continued operation.

Maintenance Schedule

Recommended maintenance tasks and their frequency.

Service

Guidelines for contacting qualified service technicians.

8. Hot Gas Bypass

9. Hot Gas Reheat (Modulating)

Pressure – Temperature Chart R-410A