Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS48-F32 HT563572
n
Mmax
1033 t
Mmax
710
n
Bmax
981 t
Bmax
680
1/s °C
SOLD06 00180 12 50 50
Year 2016
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2412 English
TPS48-F32
Original Operation Manual

Table of Contents

Questions and Answers

  • J
    Jennifer ThomasAug 28, 2025
    How to deal with rubbing of rotating parts in ABB Industrial Equipment?
    • J
      Jeremiah ValenzuelaAug 28, 2025
      If you notice rubbing of rotating parts in your ABB Industrial Equipment, contact an ABB Turbocharging Service Station if there is any doubt about the extent of the rubbing. Also, have a dimension check carried out by an ABB Turbocharging Service Station.
  • A
    Ashley GutierrezSep 3, 2025
    What to do if ABB HT563572 has charge air pressure too low?
    • A
      Adam StevensSep 3, 2025
      If the charge air pressure is too low, there could be several reasons. The air receiver or the gas piping between the engine and the turbine might be leaking. A poorly adjusted injection system also can cause this issue, so correct it. The manometer display might be providing a wrong reading, so replace the manometer, or the line to the manometer might be leaking, so repair the leak. A contaminated filter silencer causing excessive loss of pressure can also be the reason, so clean it. In some cases, the compressor/turbine might be damaged, which requires contacting an ABB Turbocharging Service Station. High exhaust counterpressure can also cause low charge air pressure, so clean or repair the boiler or exhaust silencer.
  • D
    Douglas BarnettAug 27, 2025
    What causes fouling of the compressor in my ABB charger?
    • R
      Rebecca IbarraAug 28, 2025
      Fouling of the compressor in your ABB charger, due to the feeding in of ventilation gases, may result from: * Heavy fouling of the compressor components: Clean compressor. * Material of compressor wheel corroded: Check the fuel and its corrosive components, and change fuel if necessary.
  • J
    Jeffery ClarkSep 18, 2025
    What causes turbocharger surging in ABB Marine Equipment?
    • A
      Alyssa TaylorSep 18, 2025
      Turbocharger surging can occur if the guard in front of the turbocharger is contaminated or damaged (clean or replace it), if the filter silencer or diffuser is contaminated (clean it), or if the cooler is contaminated (clean it).
  • S
    Steven RobersonSep 23, 2025
    What to do if there is fouling of the compressor due to the feeding in of ventilation gases in ABB Marine Equipment?
    • Q
      qwilliamsonSep 23, 2025
      Fouling of the compressor due to the feeding in of ventilation gases can be caused by heavy fouling of the compressor components (clean compressor) or increased vibrations and compressor blade damage (correct the feed of ventilation gases according to instructions of engine builder).
  • S
    shannonlisaSep 6, 2025
    What to do if the charge air pressure is too low in ABB Industrial Equipment?
    • S
      smithkatelynSep 7, 2025
      If your ABB Industrial Equipment experiences charge air pressure that is too low, several factors could be responsible. You can repair any leaks in the air receiver or correct a poorly adjusted injection system. Additionally, you should replace the manometer if the display is wrong, or repair the leak if the line to the manometer is leaking. Clean the filter silencer if it is contaminated, causing excessive pressure loss. Finally, clean or repair the boiler or exhaust silencer if the exhaust counterpressure is too high.
  • S
    shawn43Sep 10, 2025
    Why is my ABB Industrial Equipment having a sluggish start-up?
    • A
      adamsleeSep 10, 2025
      If your ABB Industrial Equipment experiences a sluggish start-up, it could be due to a few reasons. The turbocharger might be contaminated and need cleaning. Alternatively, there may be damage to the bearing, in which case you should contact an ABB Turbocharging Service Station. Other potential causes include a rubbing rotor or a foreign object present in the turbocharger.
  • C
    Courtney CrawfordSep 16, 2025
    What to do if lubricating oil pressure is too low in ABB Marine Equipment?
    • A
      Angela GraySep 17, 2025
      If the lubricating oil pressure is too low, it could be due to several reasons. The oil filter might be heavily contaminated (clean it), the oil pump in the lubricating system could be defective (check / replace it), the manometer display might be wrong (replace the manometer), or the rotor axial clearance might be too large (contact an ABB Turbocharging Service Station).
  • C
    Cynthia JordanAug 26, 2025
    Why is there a reduction in speed in my ABB charger?
    • J
      Joseph SmithAug 26, 2025
      A reduction in speed in your ABB charger can stem from: * Defects of connected cylinders when pulse charging: Contact the enginebuilder. * Heavy contamination of the turbine: Clean it. * Damaged rotor components or bearing: Contact an ABB Turbocharging Service Station. * Defects such as leaks in the exhaust gas pipes or charge air ducts: Make repairs.
  • J
    juliesmithAug 25, 2025
    Why is the charge air pressure too high in my ABB charger?
    • D
      Danielle MorrisAug 26, 2025
      If the charge air pressure is too high in your ABB charger, it may be due to: * A malfunctioning injection system: Repair it or contact the manufacturer. * A poorly adjusted injection system: Correct it. * Engine performance higher than expected: Check engine performance. * Manometer display wrong: Replace the manometer.

ABB HT563572 Specifications

General IconGeneral
CategoryIndustrial Equipment
ManufacturerABB
Product TypeCircuit Breaker
Mechanical Life20000 cycles
Electrical Life10000 cycles
StandardsIEC