EasyManua.ls Logo

ABB HT565037 - User Manual

ABB HT565037
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS48-F33 HT565037
n
Mmax
1010 t
Mmax
680
n
Bmax
959 t
Bmax
650
1/s °C
00180 12 25 25
Year 2016
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2412 English
TPS48-F33
Original Operation Manual

Table of Contents

Questions and Answers

  • E
    edwarddillonSep 4, 2025
    Why is there an increase in speed in my ABB HT565037 Industrial Equipment?
    • T
      Tiffany SmithSep 4, 2025
      An increase in speed in your ABB Industrial Equipment could be due to a heavily contaminated nozzle ring (with 4-stroke application). If this is the case, you should contact an ABB Turbocharging Service Station.
  • D
    David RiveraSep 4, 2025
    Why is my ABB HT565037 making noises during run-down?
    • R
      Ricky TerrySep 5, 2025
      If you are experiencing noises during run-down of your ABB Industrial Equipment, it could be due to a contaminated turbocharger, which requires cleaning. Alternatively, it could be caused by a damaged bearing, in which case you should contact an ABB Turbocharging Service Station.
  • B
    Brandy LynchSep 5, 2025
    Why is the run-down time too short for my ABB HT565037 Industrial Equipment?
    • P
      Patrick LambertSep 5, 2025
      If the run-down time is too short for your ABB Industrial Equipment, it could be because the turbocharger is contaminated, and cleaning it may solve the problem. Another possibility is a damaged bearing, in which case you should contact an ABB Turbocharging Service Station.
  • B
    Billy MorganSep 6, 2025
    What causes reduced fatigue strength in ABB Industrial Equipment compressor wheel?
    • B
      Bradley WrightSep 6, 2025
      If the material of compressor wheel is corroded, causing reduced fatigue strength of the compressor wheel and compressor blade failure in your ABB Industrial Equipment, check the fuel and its corrosive components, and change fuel if necessary.
  • A
    Andrew JonesSep 6, 2025
    What to do if there is no signal from speed sensor in ABB HT565037 Industrial Equipment?
    • C
      christophermullinsSep 7, 2025
      If you are not getting a signal or the amplitude is poor on your ABB Industrial Equipment, it may be due to a fitting error. The screw plug for the sensor might have been fitted with an additional gasket (copper ring). Remove this gasket when fitting the speed sensor to ensure the correct distance from the sensor tip to the signal-generating sealing disc.

ABB HT565037 Specifications

General IconGeneral
TypeMolded Case Circuit Breaker
ModelHT565037
Rated Current630 A
Rated Voltage690 V AC
Breaking Capacity50 kA
Poles3
MountingFixed

Related product manuals