Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS48-F33 HT565468
n
Mmax
1027 t
Mmax
650
n
Bmax
1007 t
Bmax
620
1/s °C
SGAK02 00180 12 50 50
Year 2016
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2412 English
TPS48-F33
Original Operation Manual

Table of Contents

Questions and Answers

  • S
    Sharon MaloneSep 4, 2025
    Why is there an increase in speed in my ABB HT565468 Industrial Equipment?
    • N
      nsparksSep 4, 2025
      An increase in speed in your ABB Industrial Equipment could be due to a heavily contaminated nozzle ring (with 4-stroke application). If this is the case, you should contact an ABB Turbocharging Service Station.
  • J
    Jasmine WilliamsSep 4, 2025
    Why is my ABB HT565468 making noises during run-down?
    • B
      Brandon MillerSep 5, 2025
      If you are experiencing noises during run-down of your ABB Industrial Equipment, it could be due to a contaminated turbocharger, which requires cleaning. Alternatively, it could be caused by a damaged bearing, in which case you should contact an ABB Turbocharging Service Station.
  • D
    Dr. Olivia TaylorSep 5, 2025
    Why is the run-down time too short for my ABB Industrial Equipment?
    • C
      Christopher TylerSep 5, 2025
      If the run-down time is too short for your ABB Industrial Equipment, it could be because the turbocharger is contaminated, and cleaning it may solve the problem. Another possibility is a damaged bearing, in which case you should contact an ABB Turbocharging Service Station.
  • A
    Amanda WilliamsSep 6, 2025
    What causes reduced fatigue strength in ABB HT565468 Industrial Equipment compressor wheel?
    • B
      bishopdarrenSep 6, 2025
      If the material of compressor wheel is corroded, causing reduced fatigue strength of the compressor wheel and compressor blade failure in your ABB Industrial Equipment, check the fuel and its corrosive components, and change fuel if necessary.
  • K
    Kristen FloresSep 6, 2025
    What to do if there is no signal from speed sensor in ABB HT565468?
    • S
      stacyturnerSep 7, 2025
      If you are not getting a signal or the amplitude is poor on your ABB Industrial Equipment, it may be due to a fitting error. The screw plug for the sensor might have been fitted with an additional gasket (copper ring). Remove this gasket when fitting the speed sensor to ensure the correct distance from the sensor tip to the signal-generating sealing disc.