Questions and Answers

  • B
    bboydAug 27, 2025
    What causes fouling of the compressor in my ABB charger?
    • W
      wrightcharlesAug 28, 2025
      Fouling of the compressor in your ABB charger, due to the feeding in of ventilation gases, may result from: * Heavy fouling of the compressor components: Clean compressor. * Material of compressor wheel corroded: Check the fuel and its corrosive components, and change fuel if necessary.
  • J
    James PowellSep 16, 2025
    What to do if lubricating oil pressure is too low in ABB Marine Equipment?
    • R
      randy61Sep 17, 2025
      If the lubricating oil pressure is too low, it could be due to several reasons. The oil filter might be heavily contaminated (clean it), the oil pump in the lubricating system could be defective (check / replace it), the manometer display might be wrong (replace the manometer), or the rotor axial clearance might be too large (contact an ABB Turbocharging Service Station).
  • T
    Tanner LewisAug 28, 2025
    How to deal with rubbing of rotating parts in ABB Industrial Equipment?
    • E
      Eric ClarkAug 28, 2025
      If you notice rubbing of rotating parts in your ABB Industrial Equipment, contact an ABB Turbocharging Service Station if there is any doubt about the extent of the rubbing. Also, have a dimension check carried out by an ABB Turbocharging Service Station.
  • A
    Amy DoyleAug 29, 2025
    How to fix sluggish start-up of ABB HT570165 Industrial Equipment?
    • A
      Anna BaileyAug 29, 2025
      A sluggish start-up of your ABB Industrial Equipment can occur if the turbocharger is contaminated. In this case, clean the turbocharger. Another possible cause is a damaged bearing. If the bearing is damaged, contact an ABB Turbocharging Service Station.
  • B
    Brittany SmithAug 29, 2025
    What to do if ABB Industrial Equipment is vibrating?
    • W
      William PattersonAug 29, 2025
      If your ABB Industrial Equipment is vibrating, it may be due to rotor unbalance. In this situation, contact an ABB Turbocharging Service Station.
  • D
    Dr. Brian DavidsonSep 23, 2025
    What to do if there is fouling of the compressor due to the feeding in of ventilation gases in ABB Marine Equipment?
    • J
      Jocelyn SmithSep 23, 2025
      Fouling of the compressor due to the feeding in of ventilation gases can be caused by heavy fouling of the compressor components (clean compressor) or increased vibrations and compressor blade damage (correct the feed of ventilation gases according to instructions of engine builder).
  • J
    Joseph ReedSep 14, 2025
    What to do if ABB Battery Charger has vibrations?
    • L
      lauraunderwoodSep 15, 2025
      If your ABB Battery Charger is experiencing vibrations, it may be due to rotor unbalance. Contact an ABB Turbocharging Service Station for assistance.
  • Y
    yrodriguezSep 12, 2025
    Why is my ABB HT570165 Industrial Equipment experiencing a sluggish start-up?
    • L
      Leslie AcevedoSep 12, 2025
      A sluggish start-up of your ABB Industrial Equipment can occur due to several reasons. The turbocharger may be contaminated, in which case you should clean it. Another cause may be damaged bearing, in which case you should contact an ABB Turbocharging Service Station. It may also be caused by a rubbing rotor or a foreign object in the turbocharger.
  • M
    Mark EllisAug 31, 2025
    What to do if ABB HT570165 Industrial Equipment has vibration?
    • X
      xbauerAug 31, 2025
      If your ABB Industrial Equipment is vibrating, it could be due to rotor unbalance, in which case you should contact an ABB Turbocharging Service Station. Other potential causes include a damaged turbine or compressor, or a damaged bearing.
  • M
    Madison OrtizAug 31, 2025
    Why is my ABB HT570165 start-up sluggish?
    • H
      hannah15Aug 31, 2025
      A sluggish start-up of your ABB Industrial Equipment can be attributed to several factors. The turbocharger may be contaminated and needs cleaning. Alternatively, there could be a damaged bearing, in which case you should contact an ABB Turbocharging Service Station. Other possible causes include a rubbing rotor or a foreign object present in the turbocharger.