n
Mmax
865 t
Mmax
710
n
Bmax
822 t
Bmax
680
1/s °C
SOLD06 00250 12 50 50
Year 2017
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2412 English
TPS52-F32
Original Operation Manual

Table of Contents

Questions and Answers

  • D
    david00Sep 3, 2025
    What to do if ABB Battery Charger has rubbing of rotating parts?
    • S
      Stephanie EricksonSep 3, 2025
      If you notice rubbing of rotating parts in your ABB Battery Charger, and you have any doubt about the extent of the rubbing, it's crucial to contact an ABB Turbocharging Service Station.
  • P
    phughesSep 3, 2025
    How to fix sluggish start-up in ABB Industrial Equipment?
    • A
      Audrey RoblesSep 3, 2025
      A sluggish start-up of your ABB Industrial Equipment could be caused by a contaminated turbocharger, which you can resolve by cleaning it. It may also be due to a damaged bearing, in which case you should contact an ABB Turbocharging Service Station. Other potential causes are rubbing rotor or a foreign object in the turbocharger.
  • C
    Christopher WhiteSep 4, 2025
    Why is my ABB HT572708 experiencing vibrations?
    • J
      Jeffrey OlsonSep 4, 2025
      Vibrations in your ABB Industrial Equipment can be due to several reasons. It could be caused by rotor unbalance, in which case you should contact an ABB Turbocharging Service Station. Other potential causes include a damaged turbine or compressor, or a damaged bearing.
  • S
    Shawn RussellSep 4, 2025
    Why is the exhaust gas temperature too high in my ABB Battery Charger?
    • B
      Brian MooreSep 5, 2025
      If the exhaust gas temperature of your ABB Battery Charger is too high, it could be due to several reasons: a malfunctioning injection system (repair it or contact the manufacturer), air starvation (clean the filter silencer), high exhaust counterpressure (clean or repair the boiler or exhaust silencer), a damaged or eroded turbine (contact an ABB Turbocharging Service Station), a contaminated cooler (clean it), low cooling water volume (top up the water), high cooling water entry temperature (inspect/clean the cooling system), or inadequate ventilation (improve the ventilation).
  • C
    Christopher KnightSep 5, 2025
    What to do if ABB Battery Charger speed is reduced?
    • S
      Shane WilkersonSep 5, 2025
      If your ABB Battery Charger is experiencing a reduction in speed, it could be due to defects of connected cylinders when pulse charging (contact the enginebuilder), heavy contamination of the turbine (clean it), damaged rotor components or bearing (contact an ABB Turbocharging Service Station), or defects such as leaks in the exhaust gas pipes or charge air ducts (make repairs).
  • G
    gpayneSep 6, 2025
    Why is the charge air pressure too low in my ABB Battery Charger?
    • S
      Shelly BakerSep 6, 2025
      If your ABB Battery Charger's charge air pressure is too low, it could be due to a leaking air receiver (make repairs), a poorly adjusted injection system (correct it), a wrong manometer display (replace the manometer), a leaking line to the manometer (repair the leak), a contaminated filter silencer causing excessive pressure loss (clean it), a damaged compressor/turbine (contact an ABB Turbocharging Service Station), or high exhaust counterpressure (clean or repair the boiler or exhaust silencer).
  • N
    Nicole LamSep 6, 2025
    What to do if ABB Battery Charger is surging?
    • P
      Pamela GonzalezSep 6, 2025
      If your ABB Battery Charger is surging, it may be because the guard in front of the turbocharger is contaminated or damaged (clean or replace it), the filter silencer or diffuser is contaminated (clean it), or the cooler is contaminated (clean it). It could also be caused by a blocked charge air duct.
  • R
    Ryan CooperSep 7, 2025
    Why is lubricating oil pressure too low in ABB Battery Charger?
    • N
      Noah BanksSep 7, 2025
      If the lubricating oil pressure is too low in your ABB Battery Charger, it could be due to a heavily contaminated oil filter (clean it), a defective oil pump in the lubricating system (check or replace it), a wrong manometer display (replace the manometer), or a rotor axial clearance that is too large (contact an ABB Turbocharging Service Station).