Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS48-F32 HT577985
n
Mmax
1029 t
Mmax
680
n
Bmax
978 t
Bmax
650
1/s °C
SOLD08 00180 12 60 60
Year 2017
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2412 English
TPS48-F32
Original Operation Manual

Table of Contents

Questions and Answers

  • S
    sstephensonSep 23, 2025
    Why is my ABB Battery Charger start-up sluggish?
    • K
      Kelly CisnerosSep 23, 2025
      A sluggish start-up of your ABB Battery Charger can be due to several reasons. It might be caused by a contaminated turbocharger, in which case you should clean it. Other potential causes include a damaged bearing (in this case you should contact an ABB Turbocharging Service Station), a rubbing rotor, or a foreign object in the turbocharger.
  • A
    Amanda ThomasSep 3, 2025
    What to do if ABB Industrial Equipment has charge air pressure too low?
    • B
      Bobby OsborneSep 3, 2025
      If the charge air pressure is too low, there could be several reasons. The air receiver or the gas piping between the engine and the turbine might be leaking. A poorly adjusted injection system also can cause this issue, so correct it. The manometer display might be providing a wrong reading, so replace the manometer, or the line to the manometer might be leaking, so repair the leak. A contaminated filter silencer causing excessive loss of pressure can also be the reason, so clean it. In some cases, the compressor/turbine might be damaged, which requires contacting an ABB Turbocharging Service Station. High exhaust counterpressure can also cause low charge air pressure, so clean or repair the boiler or exhaust silencer.
  • A
    Anne GriffinAug 27, 2025
    What causes fouling of the compressor in my ABB charger?
    • O
      oflowersAug 28, 2025
      Fouling of the compressor in your ABB charger, due to the feeding in of ventilation gases, may result from: * Heavy fouling of the compressor components: Clean compressor. * Material of compressor wheel corroded: Check the fuel and its corrosive components, and change fuel if necessary.
  • D
    Douglas ReeseSep 18, 2025
    What causes turbocharger surging in ABB Marine Equipment?
    • J
      Jacqueline DavisSep 18, 2025
      Turbocharger surging can occur if the guard in front of the turbocharger is contaminated or damaged (clean or replace it), if the filter silencer or diffuser is contaminated (clean it), or if the cooler is contaminated (clean it).
  • A
    Andrea PatrickSep 23, 2025
    What causes increase in speed in ABB Marine Equipment?
    • K
      Kristy AdamsSep 23, 2025
      An increase in speed can be caused by a heavily contaminated nozzle ring (with 4-stroke application) (contact an ABB Turbocharging Service Station).
  • A
    April DavisSep 6, 2025
    What to do if the charge air pressure is too low in ABB HT577985?
    • E
      erinshermanSep 7, 2025
      If your ABB Industrial Equipment experiences charge air pressure that is too low, several factors could be responsible. You can repair any leaks in the air receiver or correct a poorly adjusted injection system. Additionally, you should replace the manometer if the display is wrong, or repair the leak if the line to the manometer is leaking. Clean the filter silencer if it is contaminated, causing excessive pressure loss. Finally, clean or repair the boiler or exhaust silencer if the exhaust counterpressure is too high.
  • X
    xforbesSep 10, 2025
    Why is my ABB Industrial Equipment having a sluggish start-up?
    • D
      Diana RobinsonSep 10, 2025
      If your ABB Industrial Equipment experiences a sluggish start-up, it could be due to a few reasons. The turbocharger might be contaminated and need cleaning. Alternatively, there may be damage to the bearing, in which case you should contact an ABB Turbocharging Service Station. Other potential causes include a rubbing rotor or a foreign object present in the turbocharger.
  • K
    kathryn06Sep 16, 2025
    What to do if lubricating oil pressure is too low in ABB Marine Equipment?
    • A
      Anna BatesSep 17, 2025
      If the lubricating oil pressure is too low, it could be due to several reasons. The oil filter might be heavily contaminated (clean it), the oil pump in the lubricating system could be defective (check / replace it), the manometer display might be wrong (replace the manometer), or the rotor axial clearance might be too large (contact an ABB Turbocharging Service Station).
  • M
    Melissa Perez MDSep 23, 2025
    What to do if my ABB Battery Charger has vibrations?
    • J
      Joshua BrooksSep 23, 2025
      If your ABB Battery Charger is experiencing vibrations, the rotor may be unbalanced. In this case, contact an ABB Turbocharging Service Station.
  • J
    johnsonemilyAug 25, 2025
    Why is the charge air pressure too high in my ABB charger?
    • T
      tinamorganAug 26, 2025
      If the charge air pressure is too high in your ABB charger, it may be due to: * A malfunctioning injection system: Repair it or contact the manufacturer. * A poorly adjusted injection system: Correct it. * Engine performance higher than expected: Check engine performance. * Manometer display wrong: Replace the manometer.