Table of Contents

Questions and Answers

  • M
    Malik AndrewsSep 3, 2025
    What to do if ABB Industrial Equipment has charge air pressure too low?
    • G
      Gregory HughesSep 3, 2025
      If the charge air pressure is too low, there could be several reasons. The air receiver or the gas piping between the engine and the turbine might be leaking. A poorly adjusted injection system also can cause this issue, so correct it. The manometer display might be providing a wrong reading, so replace the manometer, or the line to the manometer might be leaking, so repair the leak. A contaminated filter silencer causing excessive loss of pressure can also be the reason, so clean it. In some cases, the compressor/turbine might be damaged, which requires contacting an ABB Turbocharging Service Station. High exhaust counterpressure can also cause low charge air pressure, so clean or repair the boiler or exhaust silencer.
  • P
    Paige MercerAug 25, 2025
    Why is the charge air pressure too low in my ABB charger?
    • V
      vrileyAug 25, 2025
      If the charge air pressure is too low in your ABB charger, several factors could be responsible: * Air receiver leaking: Make repairs. * Gas piping between the engine and the turbine leaking. * Poorly adjusted injection system: Correct it. * Poorly adjusted valve control. * Manometer display wrong: Replace the manometer. * Line to manometer leaking: Repair the leak. * Contaminated filter silencer: Clean it because it causes excessive pressure loss. * Damaged compressor/turbine: Contact an ABB Turbocharging Service Station. * High exhaust counterpressure: Clean or repair the boiler or exhaust silencer.
  • M
    Meagan WilliamsAug 25, 2025
    Why is the charge air pressure too high in my ABB charger?
    • D
      Douglas RodgersAug 26, 2025
      If the charge air pressure is too high in your ABB charger, it may be due to: * A malfunctioning injection system: Repair it or contact the manufacturer. * A poorly adjusted injection system: Correct it. * Engine performance higher than expected: Check engine performance. * Manometer display wrong: Replace the manometer.
  • P
    Paula RosarioSep 10, 2025
    Why is my ABB HT580519 Industrial Equipment having a sluggish start-up?
    • A
      Ariel HahnSep 10, 2025
      If your ABB Industrial Equipment experiences a sluggish start-up, it could be due to a few reasons. The turbocharger might be contaminated and need cleaning. Alternatively, there may be damage to the bearing, in which case you should contact an ABB Turbocharging Service Station. Other potential causes include a rubbing rotor or a foreign object present in the turbocharger.
  • A
    Abigail KirkSep 17, 2025
    What to do if lubricating oil pressure is too low in ABB Marine Equipment?
    • A
      austinhuangSep 17, 2025
      If the lubricating oil pressure is too low, it could be due to several reasons. The oil filter might be heavily contaminated (clean it), the oil pump in the lubricating system could be defective (check / replace it), the manometer display might be wrong (replace the manometer), or the rotor axial clearance might be too large (contact an ABB Turbocharging Service Station).
  • B
    Brian StanleySep 6, 2025
    What to do if the charge air pressure is too low in ABB HT580519?
    • J
      John SchmidtSep 7, 2025
      If your ABB Industrial Equipment experiences charge air pressure that is too low, several factors could be responsible. You can repair any leaks in the air receiver or correct a poorly adjusted injection system. Additionally, you should replace the manometer if the display is wrong, or repair the leak if the line to the manometer is leaking. Clean the filter silencer if it is contaminated, causing excessive pressure loss. Finally, clean or repair the boiler or exhaust silencer if the exhaust counterpressure is too high.
  • R
    Rebecca LewisAug 31, 2025
    What to do if ABB Industrial Equipment has vibration?
    • N
      nancy83Aug 31, 2025
      If your ABB Industrial Equipment is vibrating, it could be due to rotor unbalance, in which case you should contact an ABB Turbocharging Service Station. Other potential causes include a damaged turbine or compressor, or a damaged bearing.
  • J
    Joseph FernandezSep 23, 2025
    What causes increase in speed in ABB Marine Equipment?
    • M
      Michael AndrewsSep 23, 2025
      An increase in speed can be caused by a heavily contaminated nozzle ring (with 4-stroke application) (contact an ABB Turbocharging Service Station).
  • Q
    qmilesSep 13, 2025
    What to do if ABB Industrial Equipment has rubbing of rotating parts?
    • J
      James WeaverSep 13, 2025
      If you suspect rubbing of rotating parts in your ABB Industrial Equipment, and you're unsure about the extent of the rubbing, it's best to contact an ABB Turbocharging Service Station. They can perform a dimension check to assess the situation.
  • A
    Andrew KerrAug 27, 2025
    What causes fouling of the compressor in my ABB charger?
    • S
      scott29Aug 28, 2025
      Fouling of the compressor in your ABB charger, due to the feeding in of ventilation gases, may result from: * Heavy fouling of the compressor components: Clean compressor. * Material of compressor wheel corroded: Check the fuel and its corrosive components, and change fuel if necessary.