Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS52-F32 HT581070
n
Mmax
862 t
Mmax
680
n
Bmax
819 t
Bmax
650
1/s °C
SOLD06 00250 16 60 60
Year 2018
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2412 English
TPS52-F32
Original Operation Manual

Table of Contents

Questions and Answers

  • C
    Christopher WalkerSep 8, 2025
    How to fix a sluggish start-up on ABB Battery Charger?
    • T
      Thomas WallaceSep 8, 2025
      If your ABB Battery Charger has a sluggish start-up, it could be due to a contaminated turbocharger (clean it) or a damaged bearing (contact an ABB Turbocharging Service Station).
  • T
    taylorashleyAug 25, 2025
    Why is my ABB HT581070 having a sluggish start-up?
    • E
      Erica RodriguezAug 25, 2025
      A sluggish start-up in your ABB Industrial Equipment can stem from several causes. It may be caused by a contaminated turbocharger, which can be resolved by cleaning it. Alternatively, it could be due to a damaged bearing, in which case you should contact an ABB Turbocharging Service Station. Other potential causes are rubbing rotor or a foreign object in the turbocharger.
  • N
    Nicole BarberAug 25, 2025
    What to do if ABB Industrial Equipment rotating parts are rubbing?
    • S
      Susan RobertsonAug 26, 2025
      If you suspect rubbing of rotating parts in your ABB Industrial Equipment, and you have any doubt about the extent of rubbing, then an ABB Turbocharging Service Station must be contacted.
  • A
    allison28Sep 18, 2025
    Why is my ABB Battery Charger turbocharger surging?
    • R
      Ronald LambertSep 18, 2025
      Turbocharger surging in your ABB Battery Charger can occur if: * The guard in front of the turbocharger is contaminated or damaged: clean or replace it. * The filter silencer or diffuser is contaminated: clean it. * The cooler is contaminated: clean it.
  • W
    william75Sep 9, 2025
    How to handle rubbing of rotating parts in ABB Industrial Equipment?
    • M
      Mary TaylorSep 9, 2025
      Rubbing of rotating parts in ABB Industrial Equipment can be normal behavior and not indicate a malfunction. However, if you have any concerns about the extent of the rubbing, it is recommended to contact an ABB Turbocharging Service Station to carry out a dimension check.
  • D
    Douglas PerrySep 13, 2025
    How to resolve vibrations in ABB Industrial Equipment?
    • J
      Justin GibsonSep 13, 2025
      Vibrations in your ABB Industrial Equipment may be caused by rotor unbalance. Contact an ABB Turbocharging Service Station to resolve this issue.
  • T
    tmanningSep 3, 2025
    How to fix sluggish start-up in ABB Industrial Equipment?
    • C
      Courtney BrightSep 3, 2025
      A sluggish start-up of your ABB Industrial Equipment could be caused by a contaminated turbocharger, which you can resolve by cleaning it. It may also be due to a damaged bearing, in which case you should contact an ABB Turbocharging Service Station. Other potential causes are rubbing rotor or a foreign object in the turbocharger.
  • L
    Linda MillerSep 4, 2025
    Why is my ABB HT581070 experiencing vibrations?
    • N
      nathaniel01Sep 4, 2025
      Vibrations in your ABB Industrial Equipment can be due to several reasons. It could be caused by rotor unbalance, in which case you should contact an ABB Turbocharging Service Station. Other potential causes include a damaged turbine or compressor, or a damaged bearing.
  • S
    smithjacobSep 23, 2025
    How to check rubbing of rotating parts in ABB HT581070?
    • Z
      Zachary TurnerSep 23, 2025
      Rubbing of rotating parts in ABB Industrial Equipment can sometimes be normal and not indicate a malfunction. To confirm, have a dimension check carried out by an ABB Turbocharging Service Station.
  • M
    Michelle LeeAug 29, 2025
    Why is my ABB Industrial Equipment start-up sluggish?
    • N
      Nathan ReedAug 29, 2025
      A sluggish start-up of your ABB Industrial Equipment can be due to several reasons. It might be caused by a contaminated turbocharger, which requires cleaning. Other potential causes include a damaged bearing, a rubbing rotor, or a foreign object present in the turbocharger.