Operation Manual / A130-H.. - A140-H..
9 Dismantling and fitting / 9.6 Removing the compressor casing
© Copyright 2021 ABB. All rights reserved. HZTL4030_EN Rev.G July 2021
Dismantling the wall insert
Fig.40: Dismantling the wall insert
1. Knock the wall insert(77000) out of the compressor casing(72000) with a plastic tip
hammer.
2. Attach swivel lifting eye(S) to the compressor casing(72000) and the lifting gear.
3. Lift up the compressor casing(72000).
4. Remove and dispose of the O-ring(77005).