Page #1 background image
Turbocharging
Operation Manual / A155-M56
HT608603
Document identification
Document number HZTL4032
Revision R
Language English
Original Operation Manual
Product identification
Serial number HT608603
Customer part number
Delivery date (yyyy-mm-dd) 2021-12-21
Weight 1800 kg
Operating limits according to rating plate
Speed limit in test rig operation only
n
Mmax
458 1/s
Speed limit during operation
n
Bmax
444 1/s
Gas inlet temperature limit in test rig operation only
t
Mmax
630 °C
Gas inlet temperature limit during operation
t
Bmax
600 °C

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ABB HT608603 and is the answer not in the manual?

ABB HT608603 Specifications

General IconGeneral
Voltage Rating400 V AC
StandardsIEC 60947-2
Mechanical Life20, 000 operations
Electrical Life10000 cycles
TypeMiniature Circuit Breaker
Number of Poles3P