Turbo Systems Switzerland Ltd
Operation Manual / A175-M66
HT612273
Document identification
Document number HZTL4033
Revision K
Language English
Original Operation Manual
Product identification
Serial number HT612273
Customer part number
Delivery date (yyyy-mm-dd) 2022-05-11
Weight 4600 kg
Operating limits according to rating plate
Speed limit in test rig operation only
n
Mmax
316 1/s
Speed limit during operation
n
Bmax
312 1/s
Gas inlet temperature limit in test rig operation only
t
Mmax
650 °C
Gas inlet temperature limit during operation
t
Bmax
620 °C

Table of Contents

Questions and Answers

  • K
    Kenneth YoungAug 10, 2025
    Why is there a delayed start-up in my ABB HT612273 Industrial Equipment?
    • W
      Wendy BryantAug 10, 2025
      A delayed start-up in your ABB Industrial Equipment could be due to several reasons: a contaminated turbocharger (clean it with periodic maintenance), damaged bearing (contact ABB Turbocharging Service Station), rotor rubbing, or a foreign object present in the turbocharger.
  • K
    Katherine AguilarAug 25, 2025
    What to do if there is rubbing of rotating parts in ABB HT612273?
    • M
      Michael RobinsonAug 25, 2025
      If there is any doubt about the extent of the rubbing, contact an ABB Turbocharging Service Station. Have a dimension check carried out by an ABB Turbocharging Service Station.