Operation 4
Stopping the engine 4.5 Page 54
© Copyright 2016 ABB. All rights reserved.
August 2017HZTL2412_ENRevision F
Stopping the engine
4.5
CAUTION
Stopping the engine of oil-cooled turbocharger version
Heat in the turbocharger must be dissipated by the further circulating
lubricating oil.
τ Post-lubricate for 15 … 20 minutes.
τ Maintain oil pressure of 0.5 … 1.0 bar for post-lubrication.
CAUTION
Stopping the engine of water-cooled turbocharger version
Heat in the turbocharger must be dissipated.
τ Allow turbocharger cooling water to run for 15 … 20 minutes after
stopping engine.
τ Allow oil lubrication to continue running until rotor comes to a stop.
Further post-lubrication is not required and not recommended.
4.5

Table of Contents

Other manuals for ABB HT842068

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB HT842068 and is the answer not in the manual?

ABB HT842068 Specifications

General IconGeneral
Product IDHT842068
TypeMiniature Circuit Breaker
ABB Type DesignationS201-C16
Catalog DescriptionS201-C16 Miniature Circuit Breaker
Mechanical Life20000 operating cycles
Electrical Life10000 operating cycles
MountingDIN rail
Operating Temperature-25 ... +55 °C