Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS 52E01 HT842160
n
Mmax
876 t
Mmax
650
n
Bmax
832 t
Bmax
620
1/s °C
00250 12 50 50
Year 2016
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2410 English
TPS 52E01
Original Operation Manual

Table of Contents

Questions and Answers

  • M
    Matthew BeckAug 23, 2025
    Why is my ABB HT842160 vibrating?
    • R
      Rhonda WareAug 25, 2025
      If your ABB Industrial Equipment is experiencing vibrations, it could be due to a rotor unbalance, in which case you should contact an ABB Turbocharging Service Station. It may also be caused by a damaged turbine, compressor, or bearing.
  • D
    Dennis HumphreySep 1, 2025
    Why is the exhaust gas temperature too high in my ABB Battery Charger?
    • W
      william80Sep 1, 2025
      High exhaust gas temperature in your ABB Battery Charger can stem from several issues: * A malfunctioning injection system, which needs repair or manufacturer consultation. * Air starvation due to a clogged filter silencer, requiring cleaning. * High exhaust counterpressure, necessitating cleaning or repair of the boiler or exhaust silencer. * A dirty cooler, which should be cleaned. * Insufficient cooling water volume, requiring a top-up. * High cooling water entry temperature, indicating a need to inspect/clean the cooling system. * Inadequate ventilation, suggesting improved ventilation.
  • J
    Julie VegaSep 1, 2025
    What to do if the charge air pressure is too low in my ABB Battery Charger?
    • A
      Amy KiddSep 1, 2025
      If the charge air pressure is too low in your ABB Battery Charger, consider these potential causes: * A leaky air receiver, which requires repair. * A maladjusted injection system, needing correction. * A faulty manometer display, which should be replaced. * A dirty filter silencer causing pressure loss, requiring cleaning. * High exhaust counterpressure, addressable by cleaning or repairing the boiler or exhaust silencer.
  • C
    Christopher WilliamsSep 2, 2025
    What causes turbocharger surging in an ABB Battery Charger and how to fix it?
    • S
      smithstacySep 2, 2025
      Turbocharger surging in your ABB Battery Charger can be caused by: * A contaminated or damaged guard in front of the turbocharger, which needs cleaning or replacement. * A contaminated filter silencer or diffuser, requiring cleaning. * A contaminated cooler, which should be cleaned.
  • J
    Jessica EatonSep 3, 2025
    Why is there a reduction in speed in my ABB Battery Charger?
    • L
      lynchdianaSep 3, 2025
      A reduction in speed in your ABB Battery Charger could be due to: * Heavy contamination of the turbine, which requires cleaning. * Defects such as leaks in the exhaust gas pipes or charge air ducts, which require repairs.
  • S
    Sabrina BrownSep 4, 2025
    What causes charge-air pressure to be too high in an ABB Battery Charger?
    • P
      Patricia YoungSep 4, 2025
      Excessive charge-air pressure in your ABB Battery Charger can result from: * A malfunction in the injection system, requiring repair or manufacturer consultation. * Injection being misaligned, which needs to be set correctly.
  • B
    Barbara ZimmermanSep 4, 2025
    What to do if lubricating oil pressure is too low in ABB Battery Charger?
    • T
      Tyler IrwinSep 5, 2025
      If the lubricating oil pressure is too low in your ABB Battery Charger, you should: * Clean a heavily contaminated oil filter. * Check or replace a defective oil pump in the lubricating system. * Replace the manometer if the display is wrong.
  • R
    rhodesdanielSep 5, 2025
    How to fix a sluggish start-up in my ABB Battery Charger?
    • H
      Hayley OlsenSep 5, 2025
      To address a sluggish start-up in your ABB Battery Charger, consider that it may be caused by a contaminated turbocharger, which needs to be cleaned.
  • A
    aaroncarlsonSep 6, 2025
    Why is my ABB Battery Charger making noises during run-down?
    • D
      Daniel GrantSep 6, 2025
      Noises during run-down in your ABB Battery Charger can occur if the turbocharger is contaminated, requiring cleaning.
  • T
    Tiffany SheppardSep 7, 2025
    Why is the run-down time too short for my ABB Battery Charger?
    • C
      Christina DrakeSep 7, 2025
      A short run-down time in your ABB Battery Charger may be due to a contaminated turbocharger, which needs cleaning.