Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS 52D01 HT842179
n
Mmax
856 t
Mmax
650
n
Bmax
813 t
Bmax
620
1/s °C
00250 8 50 50
Year 2016
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2410 English
TPS 52D01
Original Operation Manual

Table of Contents

Questions and Answers

  • G
    garciadanaSep 3, 2025
    What to do if lubricating oil pressure is too low in ABB Battery Charger?
    • I
      Isaac GregorySep 3, 2025
      If the lubricating oil pressure is too low in your ABB Battery Charger, it could be due to a heavily contaminated oil filter, which needs cleaning. Another cause could be a defective oil pump in the lubricating system, which should be checked or replaced. A wrong reading on the manometer may also be the reason, in this case you should replace the manometer. Finally, it could be due to a rotor axial clearance being too large, in which case you should contact an ABB Turbocharging Service Station.
  • J
    James RamirezSep 2, 2025
    What to do if ABB Battery Charger is surging?
    • K
      kenneth93Sep 3, 2025
      If your ABB Battery Charger is experiencing turbocharger surging, the guard in front of the turbocharger may be contaminated or damaged, requiring cleaning or replacement. Alternatively, the filter silencer or diffuser could be contaminated, in which case you should clean it. Another possibility is a contaminated cooler, which would also need cleaning.
  • H
    Henry CrawfordSep 1, 2025
    Why is the exhaust gas temperature too high in my ABB Battery Charger?
    • J
      Jermaine PearsonSep 1, 2025
      If the exhaust gas temperature of your ABB Battery Charger is too high, it could be due to several reasons. The injection system might be malfunctioning, requiring repair or manufacturer contact. There might be air starvation caused by a filter silencer clogged with dirt, which you should clean. High exhaust counterpressure could be the cause, necessitating cleaning or repair of the boiler or exhaust silencer. A contaminated cooler, low cooling water volume (top up the water), high cooling water entry temperature (inspect/clean the cooling system), or inadequate ventilation (improve ventilation) could also be responsible.
  • H
    Heather PetersonSep 1, 2025
    What to do if ABB HT842179 is vibrating?
    • R
      Robert WilliamsSep 1, 2025
      If your ABB Industrial Equipment is vibrating, it may be due to rotor unbalance. In this situation, contact an ABB Turbocharging Service Station.
  • M
    Michelle PetersonAug 31, 2025
    What to do if rotating parts of ABB Industrial Equipment are rubbing?
    • C
      Colin WestAug 31, 2025
      Rubbing of rotating parts in ABB Industrial Equipment can be normal behavior and not a malfunction. If there is any doubt about the extent of rubbing, then an ABB Turbocharging Service Station must be contacted.
  • D
    Douglas HansonAug 30, 2025
    How to deal with rubbing of rotating parts in ABB HT842179 Industrial Equipment?
    • D
      Donald WrightAug 30, 2025
      If you notice rubbing of rotating parts in your ABB Industrial Equipment, contact an ABB Turbocharging Service Station if there is any doubt about the extent of the rubbing. Also, have a dimension check carried out by an ABB Turbocharging Service Station.
  • M
    Megan BrownAug 29, 2025
    Why is my ABB Industrial Equipment experiencing a sluggish start-up?
    • C
      Christie YoungAug 29, 2025
      A sluggish start-up in ABB Industrial Equipment can occur due to several reasons. It might be caused by a contaminated turbocharger, in which case you should clean it. Alternatively, it could be due to a damaged bearing, requiring you to contact an ABB Turbocharging Service Station. Other possible causes are a rubbing rotor or a foreign object in the turbocharger.
  • M
    Melissa SmithAug 28, 2025
    How to fix sluggish start-up of ABB HT842179?
    • M
      Misty GordonAug 28, 2025
      A sluggish start-up of your ABB Industrial Equipment can occur if the turbocharger is contaminated. In this case, clean the turbocharger. Another possible cause is a damaged bearing. If the bearing is damaged, contact an ABB Turbocharging Service Station.
  • J
    jonesjoshuaAug 27, 2025
    What to do if ABB Industrial Equipment has vibrations?
    • A
      Andrew WilcoxAug 27, 2025
      If your ABB Industrial Equipment is experiencing vibrations, it could be due to a rotor unbalance. In this case, contact an ABB Turbocharging Service Station. Vibrations may also be caused by a damaged turbine or compressor, or a damaged bearing.
  • D
    Dr. Karen KingAug 26, 2025
    What to do if ABB Industrial Equipment has rubbing of rotating parts?
    • J
      Jane TrujilloAug 27, 2025
      If you suspect rubbing of rotating parts in your ABB Industrial Equipment, and you're unsure about the extent of the rubbing, it's best to contact an ABB Turbocharging Service Station. They can perform a dimension check to assess the situation.

ABB HT842179 Specifications

General IconGeneral
BrandABB
ModelHT842179
CategoryIndustrial Equipment
LanguageEnglish