Page #85 background imageLoading...
Page #85 background image
Operation Manual / TPS44-F.. - TPS61-F..
Troubleshooting
6
Malfunctions when stopping
6.4
Page 83
April 2015 HZTL2412_EN Revision E
Malfunctions when stopping
6.4
Noises during run-down
Possible causes
Elimination
Turbo-
charger
Turbocharger contaminated Clean it
Damaged bearing Contact an ABB Turbocharging
Service Station
Rubbing rotor
Foreign object in turbocharger
Run-down time too short
Possible causes
Elimination
Turbo-
charger
Turbocharger contaminated
Clean it
Damaged bearing Contact an ABB Turbocharging
Service Station
Rubbing rotor
Foreign object in turbocharger