Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS 52E01 HT842667
n
Mmax
876 t
Mmax
650
n
Bmax
832 t
Bmax
620
1/s °C
00250 12 50 50
Year 2017
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2410 English
TPS 52E01
Original Operation Manual

Table of Contents

Questions and Answers

  • D
    Dr. Lynn GonzalezSep 3, 2025
    What to do if lubricating oil pressure is too low in ABB Battery Charger?
    • P
      powelldanaSep 3, 2025
      If the lubricating oil pressure is too low in your ABB Battery Charger, it could be due to a heavily contaminated oil filter, which needs cleaning. Another cause could be a defective oil pump in the lubricating system, which should be checked or replaced. A wrong reading on the manometer may also be the reason, in this case you should replace the manometer. Finally, it could be due to a rotor axial clearance being too large, in which case you should contact an ABB Turbocharging Service Station.
  • T
    Thomas MercerSep 2, 2025
    What to do if ABB Battery Charger is surging?
    • K
      kyle55Sep 2, 2025
      If your ABB Battery Charger is experiencing turbocharger surging, the guard in front of the turbocharger may be contaminated or damaged, requiring cleaning or replacement. Alternatively, the filter silencer or diffuser could be contaminated, in which case you should clean it. Another possibility is a contaminated cooler, which would also need cleaning.
  • L
    Lance MartinSep 1, 2025
    Why is the exhaust gas temperature too high in my ABB Battery Charger?
    • A
      Amanda VaughnSep 2, 2025
      If the exhaust gas temperature of your ABB Battery Charger is too high, it could be due to several reasons. The injection system might be malfunctioning, requiring repair or manufacturer contact. There might be air starvation caused by a filter silencer clogged with dirt, which you should clean. High exhaust counterpressure could be the cause, necessitating cleaning or repair of the boiler or exhaust silencer. A contaminated cooler, low cooling water volume (top up the water), high cooling water entry temperature (inspect/clean the cooling system), or inadequate ventilation (improve ventilation) could also be responsible.
  • K
    Kaitlyn SandersAug 31, 2025
    What to do if ABB Industrial Equipment is vibrating?
    • T
      trevor37Sep 1, 2025
      If your ABB Industrial Equipment is vibrating, it may be due to rotor unbalance. In this situation, contact an ABB Turbocharging Service Station.
  • G
    Gilbert SmithAug 31, 2025
    What to do if rotating parts of ABB HT842667 Industrial Equipment are rubbing?
    • J
      jessicamaciasAug 31, 2025
      Rubbing of rotating parts in ABB Industrial Equipment can be normal behavior and not a malfunction. If there is any doubt about the extent of rubbing, then an ABB Turbocharging Service Station must be contacted.
  • J
    Jason HodgesAug 30, 2025
    How to deal with rubbing of rotating parts in ABB Industrial Equipment?
    • E
      Erin SotoAug 30, 2025
      If you notice rubbing of rotating parts in your ABB Industrial Equipment, contact an ABB Turbocharging Service Station if there is any doubt about the extent of the rubbing. Also, have a dimension check carried out by an ABB Turbocharging Service Station.
  • K
    Kayla JohnsonAug 29, 2025
    Why is my ABB Industrial Equipment experiencing a sluggish start-up?
    • R
      Roy PerezAug 29, 2025
      A sluggish start-up in ABB Industrial Equipment can occur due to several reasons. It might be caused by a contaminated turbocharger, in which case you should clean it. Alternatively, it could be due to a damaged bearing, requiring you to contact an ABB Turbocharging Service Station. Other possible causes are a rubbing rotor or a foreign object in the turbocharger.
  • A
    ashleymitchellAug 28, 2025
    How to fix sluggish start-up of ABB HT842667?
    • A
      Anthony MoodyAug 28, 2025
      A sluggish start-up of your ABB Industrial Equipment can occur if the turbocharger is contaminated. In this case, clean the turbocharger. Another possible cause is a damaged bearing. If the bearing is damaged, contact an ABB Turbocharging Service Station.
  • J
    Jessica JohnsonAug 27, 2025
    What to do if ABB HT842667 Industrial Equipment has vibrations?
    • J
      James SinghAug 27, 2025
      If your ABB Industrial Equipment is experiencing vibrations, it could be due to a rotor unbalance. In this case, contact an ABB Turbocharging Service Station. Vibrations may also be caused by a damaged turbine or compressor, or a damaged bearing.
  • Y
    Yvette ReynoldsAug 26, 2025
    What to do if ABB Industrial Equipment has rubbing of rotating parts?
    • N
      Nicholas MontoyaAug 27, 2025
      If you suspect rubbing of rotating parts in your ABB Industrial Equipment, and you're unsure about the extent of the rubbing, it's best to contact an ABB Turbocharging Service Station. They can perform a dimension check to assess the situation.