Questions and Answers

  • K
    Kelly GrimesSep 18, 2025
    What to do if measured speeds are too high on my ABB Industrial Equipment?
    • S
      shepardleslieSep 18, 2025
      If the measured speeds are too high in your ABB Industrial Equipment, it may be due to: * A contaminated sensor tip; dismantle the sensor, clean its tip, and refit the sensor using the specified tightening torque.
  • M
    Mrs. Karen WagnerAug 25, 2025
    What to do if ABB Industrial Equipment has rubbing of rotating parts?
    • K
      Kathleen SheppardAug 25, 2025
      If you suspect rubbing of rotating parts in your ABB Industrial Equipment, and you're unsure about the extent of the rubbing, it's best to contact an ABB Turbocharging Service Station. They can perform a dimension check to assess the situation.
  • O
    Omar CampbellAug 26, 2025
    How to fix a sluggish start-up in ABB HT842746 Industrial Equipment?
    • J
      Jose JohnsonAug 26, 2025
      If your ABB Industrial Equipment has a sluggish start-up, it might be due to a contaminated turbocharger, in which case you should clean it. Alternatively, a damaged bearing could be the cause, requiring you to contact an ABB Turbocharging Service Station.
  • J
    Jennifer RodriguezAug 26, 2025
    What to do if rotating parts are rubbing in ABB HT842746 Industrial Equipment?
    • T
      Tina RhodesAug 27, 2025
      If you suspect rubbing of rotating parts within your ABB Industrial Equipment, and there is any doubt about the extent of rubbing, then an ABB Turbocharging Service Station must be contacted.
  • M
    Marie GreeneSep 22, 2025
    What to do if there is no signal from the speed sensor in my ABB Industrial Equipment?
    • N
      Nicholas LoveSep 22, 2025
      If there is no signal or the amplitude is poor in your ABB Industrial Equipment, it is due to a fitting error. The screw plug for the sensor is fitted with an additional gasket (copper ring). When fitting the speed sensor, this gasket must be removed to avoid signal issues.
  • B
    Benjamin ThomasSep 23, 2025
    How to fix rubbing rotating parts in ABB HT842746?
    • J
      Jeffrey MacdonaldSep 23, 2025
      If the rotating parts of your ABB Industrial Equipment are rubbing, have a dimension check carried out by an ABB Turbocharging Service Station.
  • J
    James SerranoSep 9, 2025
    Why is the charge air pressure too high in my ABB HT842746 Industrial Equipment?
    • M
      matthewduncanSep 9, 2025
      If the charge air pressure is too high in your ABB Industrial Equipment, it could be due to: * A malfunction in the injection system; repair it or contact the manufacturer. * The injection being misaligned; set it correctly.
  • T
    thomaslindsaySep 12, 2025
    Why is there a reduction in speed in my ABB HT842746 Industrial Equipment?
    • J
      Jill DavisSep 12, 2025
      If you notice a reduction in speed in your ABB Industrial Equipment, it could be caused by: * Heavy contamination of the turbine; clean it. * Damaged rotor components or bearing; contact an ABB Turbocharging Service Station.
  • W
    Whitney McdonaldSep 3, 2025
    How to deal with rubbing of rotating parts in ABB HT842746 Industrial Equipment?
    • W
      William CastroSep 3, 2025
      If you notice rubbing of rotating parts in your ABB Industrial Equipment, and you have any doubt about the extent of the rubbing, then an ABB Turbocharging Service Station must be contacted. Also, have a dimension check carried out by an ABB Turbocharging Service Station.
  • M
    Miss Jennifer RobertsSep 1, 2025
    Why does my ABB HT842746 have vibrations?
    • B
      Brian SmithSep 1, 2025
      Vibrations in your ABB Industrial Equipment may be due to rotor unbalance. In this case, you should contact an ABB Turbocharging Service Station.