Table of Contents

Questions and Answers

  • J
    Jared FletcherSep 4, 2025
    Why is there an increase in speed in my ABB HT842983?
    • S
      sthompsonSep 4, 2025
      An increase in speed in your ABB Industrial Equipment could be due to a heavily contaminated nozzle ring (with 4-stroke application). If this is the case, you should contact an ABB Turbocharging Service Station.
  • Z
    Zachary RiveraSep 4, 2025
    Why is my ABB HT842983 Industrial Equipment making noises during run-down?
    • J
      jasmineholmesSep 5, 2025
      If you are experiencing noises during run-down of your ABB Industrial Equipment, it could be due to a contaminated turbocharger, which requires cleaning. Alternatively, it could be caused by a damaged bearing, in which case you should contact an ABB Turbocharging Service Station.
  • E
    Elizabeth GreeneSep 5, 2025
    Why is the run-down time too short for my ABB Industrial Equipment?
    • P
      Paul WilsonSep 5, 2025
      If the run-down time is too short for your ABB Industrial Equipment, it could be because the turbocharger is contaminated, and cleaning it may solve the problem. Another possibility is a damaged bearing, in which case you should contact an ABB Turbocharging Service Station.
  • R
    Robert PetersSep 6, 2025
    What causes reduced fatigue strength in ABB HT842983 Industrial Equipment compressor wheel?
    • D
      dloweSep 6, 2025
      If the material of compressor wheel is corroded, causing reduced fatigue strength of the compressor wheel and compressor blade failure in your ABB Industrial Equipment, check the fuel and its corrosive components, and change fuel if necessary.
  • M
    Martha AcevedoSep 6, 2025
    What to do if there is no signal from speed sensor in ABB Industrial Equipment?
    • J
      jay01Sep 7, 2025
      If you are not getting a signal or the amplitude is poor on your ABB Industrial Equipment, it may be due to a fitting error. The screw plug for the sensor might have been fitted with an additional gasket (copper ring). Remove this gasket when fitting the speed sensor to ensure the correct distance from the sensor tip to the signal-generating sealing disc.