Do you have a question about the ABCwaters Fleck 5600SXT and is the answer not in the manual?
Type | Water Softener |
---|---|
Model | Fleck 5600SXT |
Operating Pressure | 20-125 psi |
Control Valve | Fleck 5600SXT |
Regeneration | Demand Initiated |
Flow Rate | Up to 12 GPM |
Verify all parts are present before installation begins.
Select an optimal location considering power, drain, and water line access.
Attach the Fleck valve to the mineral tank using silicone lube and hand-tightening.
Connect the bypass valve to the Fleck meter using metal clips and screws.
Connect the yoke to the bypass valve, ensuring proper alignment and screw tightness.
Connect the drain line to the Fleck meter using Teflon tape and a hose clamp.
Prepare and connect the brine line to the Fleck meter, being careful not to overtighten.
Secure the brine well to the side wall of the brine tank using provided fittings.
Insert the brine line through the brine well to connect it to the safety float.
Connect the water softener's input and output ports to the home's water line.
Plug the Fleck meter into a power receptacle and allow the tank to fill.
Add salt and water to the brine tank as the initial programming step.
Press and hold 'Up' and 'Down' arrows to set the Day Override feature.
Configure the number of days between regeneration cycles.
Specify the time of day for the regeneration cycle.
Input the water hardness level determined by a test strip.
Configure the reserve capacity based on household water usage.