HP-60/80
HP
HP-
60/80
Air pump
Start
of production
Discontinuance of production
HP-60
1995/9
HP-80
1995/9
HP Series
STRUCTURE AND PART NAMES
HP-60/80
Filter
Cover
Semi Cover
Packing
Filter
Fitting Boss
Upper
Housing
Sound
Absorber
Casing Block
Diaphragm Ring
Diaphragm
Diaphragm
Base
SP
Switch
Safety pin+Locking
collar
Electromagnet
Actuating
Rod
L-Tube
Hose
Band
Frame
Vibration Control
Rubber
Center Plate
Gasket
Lower
Housing
Power
Cord
1
Absolute Air & Gas Ltd
C6 Bromsgrove Technology Park
Isidore Road
Bromsgrove
B60 3FJ
Tel: 01527 557006
Email: enquiries@absoluteairandgas.co.uk
www.absoluteairandgas.co.uk
Question and Answer IconNeed help?

Do you have a question about the Absolute HIBLOW HP Series and is the answer not in the manual?

Summary

Structure and Part Names

HP Series Component Identification

Identifies components of the HP Series pumps using an exploded diagram and a numbered parts list for assembly reference.

Replacing the Chamber Block

Cautionary Notes for Chamber Block Replacement

Provides essential safety warnings and precautions before and during the chamber block replacement procedure.

Removing Chamber Blocks

Details the initial steps for removing the chamber blocks, including loosening screws and detaching the L-tube.

Continuing Chamber Block Replacement

Removing Diaphragm Mounting Blocks

Explains how to detach diaphragm mounting blocks from the actuating rod and separate them.

Fitting Chamber Blocks

Guides on correctly fitting the actuating rod and securing the diaphragm mounting blocks with nuts and washers.

Safety Pin Replacement in Chamber Block

Safety Pin Replacement Procedure

Details the process for replacing a broken safety pin, including checks and installation of new parts.

Completing Chamber Block Replacement

Final Assembly Steps

Covers installing the sound absorber, upper housing, and filter components to finalize the chamber block replacement.

Replacing the Electromagnet

Cautionary Notes for Electromagnet Replacement

Provides essential safety warnings, including handling hot components and potential magnetic interference.

Electromagnet Removal Steps

Details the process for removing electromagnets, including cutting wires and loosening nuts.

Completing Electromagnet Replacement

Electromagnet Mounting and Wiring

Guides on mounting new electromagnets, installing the SP switch, and connecting wires via soldering.

Procedure Completion

Confirms the successful completion of the electromagnet replacement procedure.

Absolute HIBLOW HP Series Specifications

General IconGeneral
CategoryWater Pump
SeriesHP Series
ManufacturerAbsolute
TypeAir Pump
Air Inlet Port SizeVaries by model
Materials (Wetted Parts)Varies by model
WeightVaries by model
ApplicationsWastewater treatment
ApplicationAeration
Max Flow RateVaries by model (e.g., HP-60: 60 L/min, HP-100: 100 L/min)