Functional principle and features
25 | EN
Rest period
To increase the battery life and to prevent unnecessary radio emissions, a rest period function is
integrated in the detector. It lasts for 3 minutes after each detection.
To make it easier for you to test the detector, the rest period lasts for only 7 seconds within the first
30 minutes after installing the battery or after activating the tamper switch.
Compatible equipment
• FUAA50xxx Secvest alarm panels
• FUMO50010 Repeater Secvest
• FUMO50020 Universal module Secvest
• Wireless extensions Terxon MX and LX (IR programming)
• FU8000 and FU5000 Secvest alarm control panels
Position
The motion detector may only be installed upright
Note
To ensure trouble-free operation, the detector must NOT be installed:
• opposite heat sources or windows
• above a radiator
• close to the ground
• closer than 30 mm to the ceiling
• behind cupboards, room partitions and partition walls
• at a distance of less than 1 m from large metal structures (such as metal
doors or frames, water tanks, refrigerators), household electrical systems,
power distributors or metal pipes
• inside metal housings
• close to the main power supply, or close to water or gas pipelines
• close to high-voltage devices or electronic devices such as computers,
photocopiers or other wireless devices
• close to fluorescent lighting.
The following wall material can lead to a reduction in the wireless range:
• bricks
• steel-reinforced concrete, reinforced concrete
• corrugated sheet metal.