33
COMMUNICATION
COMMUNICATION
CAMERA ID 1
BAUD RATE 2400
RETURN
Function Description
CAMERA ID 1~255
Setting for the RS-485 camera ID (ID 0 is reserved for the control
unit)
BAUD RATE 2.400 / 4.800 / 9.600 / 115.200
Setting for the baud rate of the RS-485 communication interface.
RETURN Back to main menu
ALARM DETECT
When this function is activated, the camera sets a required zoom factor with activated switching
input. Once the set time has elapsed, the starting position is reset automatically. (The zoom factor is
not retained or will not be used again for further active switching input. The switching input must be
deactivated.)
ALARM DETECT
ALARM IN ON
ZOOM RATIO 14X
DELAY TIME 10 SEC
DEFAULT OFF
RETURN
Function Description
ALARM IN ON: Zoom factor is activated with active switching input
OFF: Zoom factor is deactivated with active switching input
ZOOM RATIO Setting for the zoom factor for active switching input
DELAY TIME Delay time in which the zoom factor remains set
DEFAULT “ON” resets the settings on this page
RETURN Back to main menu