15
AUTO MODE (LOW HUMIDITY TRIGGER)
Pressing the up or down button sets the low
humidity trigger. Your device will turn on if the
probe’s reading meets or falls below this threshold.
If the probe’s reading rises above this trigger point,
your device will be turned off. This turn-off point can
be adjusted using the buffer setting as shown on
page 21.
You may also set this trigger above the high
humidity trigger to create a specific range, in which
your device will only be on when it’s within this
range.
AUTO MODE (HIGH HUMIDITY TRIGGER)
Pressing the up or down button sets the high
humidity trigger. Your device will turn on if the
probe’s reading meets or exceeds this threshold.
If the probe’s reading falls below this trigger point,
your device will be turned off. This turn-off point can
be adjusted using the buffer setting as shown on
page 21.
You may also set this trigger below the low humidity
trigger to create a specific range, in which your
device will only be on when it’s within this range.
Note that this trigger can activate as long
as you are in AUTO Mode, even if you are
viewing a different trigger within AUTO Mode.
PM
Note that this trigger can activate as long
as you are in AUTO Mode, even if you are
viewing a different trigger within AUTO Mode.
PM