Installation Manual I Service and Troubleshooting
23
MP4010-1903
PM TASK DECRIPTION DAILY ANNUAL
Verify that the Steamer is level.
X
Verify the operation of the control panel. When a button is pressed the
display should register the input and a beep should sound.
X
Verify the operation of the indicator lamps.
X
Clean water fill sensors and overfill float with non abrasive metallic pad.
DO NOT use sandpaper.
X
(AUTO-FILL ONLY) Ensure unit fills with water to the water level line.
X
Inspect external drain-lines for leaks. Repair if found.
X X
Lubricate hinges and door latch with a food grade silicon spray
Monthly
Lubricate stand casters
Monthly
Inspect AC power cord for degradation or bare wires. Replace if defective
or suspect
X
Inspect door gasket for cuts and degradation. Replace if damaged. We
suggest replacing once a year.
X
Inspect Steam distribution panel gasket for cuts and degradation. Replace
if damaged. We suggest replacing once a year
X
Inspect and clean steam vent, condensate line fittings and hoses.
X
Inspect the control compartment for foreign particulate and any loose
wiring or connections.
X
Check Pressure Switch for correct operation. Recommend to replace
every two years.
X
Inspect external and internal water connections and condensate lines for
degradation and leaks. Replace as necessary
X
PREVENTATIVE MAINTENANCE
Note: Accutemp approved service providers should complete any tasks involving access to
electrical systems.