Error codes
When appliance status is abnormal, temperature indicator on the unit will blink and display corresponding
error code. Please refer to list below for identification of error code.
Ambient
Temperature
Sensor Malfunction
Ambient temperature sensor is loosen or is poorly connected with
the terminal of display board.
Some element of display board may have been put upside down and
cause short circuit.
Ambient temperature sensor is damaged.
Display board is damaged.
Tube Temperature
Sensor Malfunction
Temperature sensor on the evaporator is loosen or is poorly
connected with the terminal of display board.
Some element of display board may have been put upside down and
cause short circuit.
Temperature sensor on the evaporator is damaged.
Display board is damaged.
Discharge
Temperature
Sensor Malfunction
Temperature sensor on the evaporator is loosen or is poorly
connected with the terminal of display board.
Some element of display board may have been put upside down and
cause short circuit.
Discharge temperature sensor is damaged.
Display board is damaged.
Humidity Sensor
Malfunction
Humidity sensor is short-circuited.
Humidity sensor is damaged.
Display board is damaged.
High-temperature
overload protection
Ambient operation condition is bad.
The evaporator and condenser are blocked with filth.
High discharge
temperature
protection of
compressor
Abnormal system (e.g.: blockage, etc.).
Abnormal rotation speed of the motor.
System is normal, but the compressor discharge temperature sensor
is abnormal or poorly contacted.
1
Unit’s Condition: Compressor and fan motor stop. The buttons are invalid.
2
Unit’s Condition:
The compressor
stops; the fan motor stops after
30 seconds.