EasyManua.ls Logo

Ace Heating Solutions Mini-Pack - Page 35

Ace Heating Solutions Mini-Pack
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Series SR90
ITEM
CODE
SPECIFICATIONS
SERIES SR92-
INPUT
Multi input
CONTROL OUTPUT (1)
CONTROL OUTPUT (2)
(OPTION)
POWER SUPPLY
REMARKS
ANALOG OUTPUT (OPTION)
COMMUNICATION OR SV BIAS (OPTION)
EVENT OUTPUT/
HEATER BREAK ALARM (OPTION)
4
8
6
Y-
I-
P-
V-
Y-
N-
I-
P-
V-
90-
08-
0
1
2
3
0
9
MPU-Based Auto-Tuning PID Digital Controller, DIN H72 × W72 × D110mm
Thermocouple: B, R, S, K, E, J, T, N, PLII, Wre5-26 {U, L (DIN 43710)}
R.T.D.: Pt100Ω /JPt100Ω
Voltage (mV): -10~10, 0~10, 0~20,
0~50, 10~50, 0~100mV DC
Current (mA): 0~20, 4~20mA DC
Receiving impedance: 250Ω
Voltage (V): -1~1, 0~1, 0~2, 0~5, 1~5,
0~10V DC Input resistance: 500kΩ min.
Scaling Possible
For voltage and current input:
Range: -1999~9999
Span: 10~5000
Note: Inverse scaling
is not possible.
Contact: 1a, Contact capacity: 240V AC 2A/resistive load
Proportional cycle: 1~120 sec.
Current: 4~20mA DC
Load resistance: 600Ω max.
SSR drive voltage: 12V±1.5V DC/30mA max.
Proportional cycle: 1~120 sec.
Voltage: 0~10V DC
Load current: 2mA max.
Contact: 1a, Contact capacity: 240V AC 2A/resistive load
None
Proportional cycle: 1~120 sec.
Current: 4~20mA DC
Load resistance: 600Ω max. (RA when shipped)
SSR drive voltage: 12V±1.5V DC/30mA max.
Proportional cycle: 1~120 sec.
Voltage: 0~10V DC
Load current: 2mA max.
100V~240V AC±10%, 50/60Hz
24V AC/DC±10%, 50/60Hz
None
Event output (2a) Ev1, Ev2
Contact capacity: 240V AC 1A/resistive load
Event output (Ev1) + Heater break alarm (with CT30A)
Event output (Ev1) + Heater break alarm (with CT50A)
Voltage: 0~10mV DC, Output resistance: 10Ω
None
Voltage: 0~10V DC, Load current: 2mA max.
Current: 4~20mA DC, Load resistance: 300Ω max.
RS-485
None
1 point (setting range: -1999~5000), Non-voltage contact or Open collector input
RS-232C
when control output (1)
Note: Available only
is Y or P is selected.
With (Please consult before ordering.)
Open collector input rating: approx. 5V/1mA max.
Without
0
3
4
0
5
7
8
6
Note:
When you purchase a two-output type controller and use it in a one output capacity, larger overshooting or undershooting may happen as
a result of integral operation. Therefore, we recommend you to choose a one-output type.
The cause of the above-mentioned problem is that the positional relationship between the proportional band (PB) and the set value (SV)
of a one-output type controller differs from that of a two-output type.
Series SR90
ITEM
CODE
SPECIFICATIONS
SERIES
SR94-
SR93-
INPUT
Multi input
CONTROL OUTPUT (1)
POWER SUPPLY
REMARKS
OPTION
Analog output
Communication
Set value bias (S V bias)
EVENT OUTPUT/
HEATER BREAK ALARM (OPTION)
4
8
6
Y-
I-
P-
V-
Y-
I-
P-
V-
N-
08-
90-
0
1
2
3
00
08
38
68
Analog output +
Set value bias (S V bias)
48
30
40
60
05
0
9
MPU-Based Auto-Tuning PID Digital Controller, DIN H96 × W48 × D110mm
MPU-Based Auto-Tuning PID Digital Controller, DIN H96 × W96 × D110mm
Thermocouple: B, R, S, K, E, J, T, N, PLII, Wre5-26 {U, L (DIN 43710)}
R.T.D.: Pt100Ω /JPt100Ω
Voltage: -10~10, 0~10, 0~20,
0~50, 10~50, 0~100mV DC
Current (mA): 0~20, 4~20mA DC
Receiving impedance: 250Ω
Voltage (V): -1~1, 0~1, 0~2, 0~5, 0~10V DC
Load resistance: 600Ω max.
Scaling Possible
Range: -1999~9999
Span: 10~5000
Note: Inverse scaling
is not possible
Contact: 1a, Contact capacity: 240V AC 2A/resistive load
Proportional cycle: 1~120 sec.
Current: 4~20mA DC
Load resistance: 600Ω max.
SSR drive voltage: 12V±1.5V DC/30mA max.
Proportional cycle: 1~120 sec.
Voltage: 0~10V DC
Load current: 2mA max.
None
None
None
Current: 4~20mA DC, Load resistance: 300Ω max.
Voltage: 0~10mV DC, Output resistance: 10Ω
Voltage: 0~10mV DC, Output resistance: 10Ω
SV bias 1 point
Current: 4~20mA DC, Load resistance: 300Ω
max.
SV bias 1 point
Voltage: 0~10V DC, Load current: 2mA max.
SV bias 1 point
RS-485
07
RS-232C
Voltage: 0~10V DC, Load current: 2mA max.
Open collector input rating: approx. 5V/1mA max.
1 point (setting range: -1999~5000), Non-voltage contact or Open collector input
With (Please consult before ordering.)
Without
Contact: 1a, Contact capacity: 240V AC 2A/resistive load
Proportional cycle: 1~120 sec.
Current: 4~20mA DC
Load resistance: 600Ω max.
SSR drive voltage: 12V±1.5V DC/30mA max.
Proportional cycle: 1~120 sec.
Voltage: 0~10V DC
Load current: 2mA max.
100~240V AC±10%, 50/60Hz
24V AC/DC±10%, 50/60Hz
Event output (2a) Ev1, Ev2
Contact capacity: 240V AC 1A/resistive load
Event output (Ev1) + Heater break alarm (with CT30A)
Event output (Ev1) + Heater break alarm (with CT50A)
when control output (1)
Note: Available only
is Y or P is selected.
CONTROL OUTPUT (2)
(OPTION)
For voltage and current input:
Note:
When you purchase a two-output type controller and use it in a one output capacity, larger overshooting or undershooting may happen as
a result of integral operation. Therefore, we recommend you to choose a one-output type.
The cause of the above-mentioned problem is that the positional relationship between the proportional band (PB) and the set value (SV)
of a one-output type controller differs from that of a two-output type.