ACiQ DUCTED I
NVERTER
SYSTEMS
SERVICE MANUAL
A-Coils:
ACIQ-24-ACL
ACIQ-36-ACL
ACIQ-
60-ACL
AC (Cooling-Only) Condensers:
ACIQ-18-AC
ACIQ-
24-AC
ACIQ-30-AC
ACIQ-36-AC
ACIQ-48-AC
Version Date: 05-13-24

Questions and Answers

  • T
    Tamara EricksonSep 23, 2025
    What does it mean if there is a communication malfunction between adapter board and outdoor main board in my ACIQ ACIQ-24-ACL?
    • J
      jonathanmorganSep 23, 2025
      If there is a communication malfunction between the adapter board and the outdoor main board in your ACIQ Inverter, refer to TS49 for a suggested solution.
  • R
    Robert HensleyAug 23, 2025
    What does it mean if my ACIQ ACIQ-24-ACL Inverter displays an indoor / outdoor unit communication error?
    • S
      Sharon AndersonAug 23, 2025
      If your ACIQ Inverter is showing an indoor/outdoor unit communication error, refer to TS24 for the suggested solution.
  • B
    bcollinsAug 25, 2025
    What to do if ACIQ ACIQ-24-ACL reports over voltage or over low voltage protection?
    • W
      wherreraAug 26, 2025
      In case of over voltage or low voltage protection with your ACIQ Inverter, refer to TS31 for a suggested solution.
  • E
    Emily RobinsonAug 27, 2025
    What to do if my ACIQ Inverter reports a water-level alarm malfunction?
    • C
      Crystal HobbsAug 27, 2025
      If your ACIQ Inverter is experiencing a water-level alarm malfunction, refer to TS29 for a suggested solution.
  • P
    Patrick WeaverAug 27, 2025
    What to do if my ACIQ ACIQ-24-ACL Inverter has IPM malfunction or IGBT over-strong current protection?
    • J
      Jessica MelendezAug 27, 2025
      In the event of an IPM malfunction or IGBT over-strong current protection in your ACIQ Inverter, refer to TS30 for a suggested solution.
  • R
    Rachel JonesSep 16, 2025
    What does low ambient temperature protection mean for my ACIQ Inverter?
    • C
      christinecochranSep 16, 2025
      If your ACIQ Inverter is experiencing low ambient temperature protection, refer to TS42 for a suggested solution.
  • Y
    yeatonSep 13, 2025
    Why is the outdoor fan speed operating outside of the normal range on my ACIQ ACIQ-24-ACL Inverter?
    • L
      lisaoconnellSep 13, 2025
      If the outdoor fan speed of your ACIQ Inverter is operating outside the normal range, refer to TS25 for a suggested solution.
  • N
    Nicole ChavezSep 15, 2025
    What to do if my ACIQ ACIQ-24-ACL Inverter reports a mismatch between the new and old platforms?
    • M
      morenogregorySep 15, 2025
      In case of a mismatch between the new and old platforms with your ACIQ Inverter, refer to TS49 for a suggested solution.
  • C
    cyoungSep 5, 2025
    What does it mean if the condenser coil temperature sensor T3 is in open or short circuit in my ACIQ Inverter?
    • E
      Edward LopezSep 6, 2025
      If the condenser coil temperature sensor T3 in your ACIQ Inverter is in an open or short circuit, refer to TS27 for a suggested solution.
  • J
    Joseph ShortSep 3, 2025
    What to do if my ACIQ Inverter shows an inverter compressor drive error?
    • R
      Rachel GravesSep 3, 2025
      If your ACIQ Inverter reports an inverter compressor drive error, refer to TS32 for a suggested solution.

Summary

Safety Precautions

Precautions

General safety guidelines and warnings to prevent injury or damage.

Information servicing (For flammable materials)

Specific safety checks and procedures for handling flammable refrigerants.

Model Reference & External Appearance

Model Reference

Table detailing indoor and outdoor unit model numbers and capacities.

External Appearance

Illustrations showing the physical design of indoor and outdoor units.

Indoor Unit-A-COIL

Dimensional Drawings

Detailed measurements and dimensions for the indoor A-COIL unit.

Introduction

Overview of indoor coil installation on multipose furnaces.

24 V Coil Interface

System Introduction

Components and layout of the 24V coil interface system.

Main Functions Of 24 V Coil Interface

Key functions and features of the 24V coil interface.

Ensure you have the following parts

List of components required for installation.

Dimensions

Physical dimensions of the 24V coil interface unit.

Wiring Diagram

Schematic illustrating electrical connections for the 24V coil interface.

DIP Switch Definitions

Explanation of DIP switch settings for unit configuration.

Control Signals To The Furnace

Standard thermostat control signals for furnace integration.

Electrical Characteristics

Specifications for power, voltage, and wire diameters.

Outdoor Unit

Dimensional Drawings

Technical drawings and dimensions for various outdoor unit panel plates.

Service Place

Required clearances and installation space for the outdoor unit.

Capacity Correction Factor for Height Difference

Factors to adjust cooling capacity based on height and pipe length.

Noise Criterion Curves

Graphs showing sound pressure levels at different frequencies.

Refrigerant Cycle Diagrams

Schematic showing the refrigerant flow and pipe sizing.

Electrical Wiring Diagrams

Wiring diagrams for outdoor units and printed circuit boards.

Installation

Installation Overview

Step-by-step guide to the overall installation process.

Location Selection

Guidelines for choosing an optimal and safe installation location.

Indoor Unit Installation

Procedures for installing the indoor evaporator coils.

Outdoor Unit Installation

Steps for mounting and connecting the outdoor unit.

Drainage Pipe Installation

Instructions for connecting the condensate drain line.

Refrigerant Pipe Installation

Guidelines for connecting refrigerant pipes, including length and flaring.

Vacuum Drying and Leakage Checking

Procedures for evacuating the system and testing for leaks.

Additional Refrigerant Charge

Method for calculating and adding refrigerant charge.

Engineering of Insulation

Proper insulation techniques for refrigerant and drainage pipes.

Engineering of Electrical Wiring

Best practices for field wiring and connections.

Test Operation

Steps for verifying proper unit function after installation.

Maintenance

First Time Installation Check

Essential checks performed after initial installation.

Refrigerant Recharge

Procedure for recharging the system with refrigerant.

Re-Installation

Steps for collecting refrigerant when removing the unit.

Product Features

Display Function

Table showing display codes for various operating modes.

Safety Features

Protective mechanisms and automatic shutdown functions.

Basic Functions

Overview of unit abbreviations and fan/mode operations.

Troubleshooting

Safety Caution

Important safety warnings before performing troubleshooting.

General Troubleshooting

Error codes for indoor units and corresponding solutions.

Outdoor Unit Point Check Function

Display codes for checking outdoor unit status and parameters.

Engineering Mode

Procedures for accessing system data and advanced settings.

Error Diagnosis and Troubleshooting Without Error Code

Common problems and potential causes without specific error codes.

Quick Maintenance by Error Code

Table mapping error codes to required replacement parts.

Troubleshooting by Error Code

Detailed diagnosis and solutions for specific error codes.

Appendix

Temperature Sensor Resistance Value Table for T1, T2, T3, and T4 (°C - K)

Resistance values for temperature sensors at various temperatures.

Temperature Sensor Resistance Value Table for TP (for some units)(°C -K)

Resistance values for TP temperature sensor at various temperatures.

Pressure On Service Port

Refrigerant pressure charts for cooling operation.

ACIQ ACIQ-24-ACL Specifications

General IconGeneral
Output Voltage120V AC
Output WaveformPure Sine Wave
Frequency60 Hz
Protection FeaturesOverload, Over Temperature, Short Circuit
Operating Temperature-20 to 40°C
Efficiency90%