J
Jose ArnoldAug 12, 2025
Why is there no grease draw-off in my ACO Haustechnik Lipator-S-RA Industrial Equipment?
- KKevin HernandezAug 12, 2025
If there is no grease draw-off in your ACO Haustechnik Industrial Equipment, several factors could be at play. First, ensure that the control has a power supply; if not, restore it. Next, verify that automatic operation is enabled. A full grease collecting barrel will also prevent draw-off, so change it if necessary. Check if the grease is flowable by inspecting the heating rod, and replace it if needed. Additionally, tripped solenoid valves can cause this issue, so switch the miniature circuit breakers back on. If they trip again, inspect and replace any defective parts in the solenoid valve or pneumatic ball valve. Finally, ensure there is a compressed air supply by checking the compressor and hoses, and verify that the water level is adequate by checking the freshwater supply.