Display
Message
Probable
Cause
Corrective
Action
Needed
CLOCK
FAIL
The
Real Time
Clock rs
missing
or
inoperative
Replace
the
CPU board.
Set
the
date
and
time
EMPTY
GRNDS
rBlN
Grounds
bin is full.
Empty
grounds
bin
Must
be
removed
for
at least
6 seconds
to
rCSI.
FRONT
PANEL
FAIL
Bad
connection
between
CPU
board
and frront
panel
Check
cable
from
front
panelto
CPU board.
Defective
front
oanel. Replace
the front
panel
circuit
board.
FRONT
PANEL
OPEN
Open
circuit
at
front
panel
or left
door.
Close
doors
Check
using
alternate
magnet
and
"Test
Routines/Front
Panel".
GROUNDS
BIN
OUT
Open
circuit
at bin
switch.
Grounds
bin is removed.
Ensure
that
grounds
bin is
pushed
in
completely.
Check
using
alternate
magnet
and
"Test
Routines/Grnds
Bin
Switch."
INVALID
STOP
L
The
left
piston
was not
able
to
complete
its
specified
motion.
Check
left
drrve
components
INVALID
STOP
R
The
right
piston
was not
able
to
complete
its
specified
motion.
Check
right
drive
components.
L DRIVE
TIMEOUT
Left
piston
took
too
long
to
complete
a movement
Check
left
drive
components.
L
SENSOR
FAIL
Left
piston
reference
sensor
has
failed
or is
out
of
position.
Check
the
left
piston
reference
sensor
for
correct
position
and
proper
operation
OUT
OF
BEANS
No
power
to
grinder
Check
fuses
in
AC
drawer.
R
DRIVE
TIMEOUT
Rrght
piston
took
too
long
to
complete
a movement.
Check
right
drive
components.
R
SENSOR
FAIL
Right
piston
reference
sensor
has
failed
or is
out
of
position.
Check
the
right
piston
reference
sensor
for
correct
position
and
proper
operation.
REFR
TEMP
XX.X
F
where
xx.x
is
the
current
temperature
Refrigerator
temperature
exceeds
NSF-specified
maxlmum (41"F).
Check
refrigeration
componenrs
Keep
refer
door
closed
for
two
hours
minimum.
Acorto
2000s/i
Technical
Support
18-3